Accelerated activation of the coagulation pathway during cardiopulmonary bypass in aortic replacement surgery: a prospective observational study

نویسندگان

  • Hideo Sato
  • Koji Yamamoto
  • Akihito Kakinuma
  • Yoshinori Nakata
  • Shigehito Sawamura
چکیده

BACKGROUND Any form of surgery or tissue damage causes release of tissue factor into the circulation. This may lead to the accelerated consumption of coagulation factors, resulting in severe consumptive coagulopathy. In this study, we compared the molecular markers involved in coagulation activation during cardiopulmonary bypass (CPB) between patients who underwent aortic replacement surgery and those who underwent valve surgery. METHODS This prospective observational study was performed in each 14 patients who underwent aortic replacement surgery or valve surgery. We evaluated the differences in the levels of fibrinogen, activated factor VII (FVIIa), thrombin-antithrombin complex (TAT), and soluble fibrin monomer complex (SFMC) during surgery between these two groups. RESULTS The change in fibrinogen levels showed no difference between the groups. The magnitude of increase in TAT was much larger in patients who underwent aortic replacement surgery than in those who underwent valve surgery (173.6 vs. 49.4 ng/mL; p = 0.0001). More importantly, the elevation of FVIIa was significantly higher in patients who underwent aortic replacement (28.5 vs. 19.0 mU/mL; p = 0.0122). The magnitude of increase in SFMC was also larger in the aortic replacement surgery. CONCLUSIONS The activation of coagulation during CPB was dramatically higher in the aortic replacement surgery compared with the valve surgery, probably owing to the activation of the extrinsic coagulation pathway in the former. This could potentially exacerbate consumptive coagulopathy after CPB termination in patients who underwent aortic replacement, possibly resulting in massive hemorrhage due to impaired hemostasis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sutureless Aortic Valve Replacement International Registry (SU-AVR-IR): design and rationale from the International Valvular Surgery Study Group (IVSSG).

BACKGROUND Sutureless aortic valve replacement (SU-AVR) is an innovative approach which shortens cardiopulmonary bypass and cross-clamp durations and may facilitate minimally invasive approach. Evidence outlining its safety, efficacy, hemodynamic profile and potential complications is replete with small-volume observational studies and few comparative publications. METHODS Minimally invasive ...

متن کامل

Sutureless aortic valve replacement.

The increasing incidence of aortic stenosis and greater co-morbidities and risk profiles of the contemporary patient population has driven the development of minimally invasive aortic valve surgery and percutaneous transcatheter aortic valve implantation (TAVI) techniques to reduce surgical trauma. Recent technological developments have led to an alternative minimally invasive option which avoi...

متن کامل

Effects of fibrinogen concentrate as first-line therapy during major aortic replacement surgery: a randomized, placebo-controlled trial.

BACKGROUND Fibrinogen is suggested to play an important role in managing major bleeding. However, clinical evidence regarding the effect of fibrinogen concentrate (derived from human plasma) on transfusion is limited. The authors assessed whether fibrinogen concentrate can reduce blood transfusion when given as intraoperative, targeted, first-line hemostatic therapy in bleeding patients undergo...

متن کامل

نتایج کاربرد بالون پمپ داخل آئورت در بیماران جراحی قلبIntra-Aortic Ballon Pump Outcome in Cardiac Surgical Patients

        Background & Aim: Intra-aortic ballon pump(IABP) is a mechanical device that has become an accepted treatment modality for patients with severely compromised hemodynamics. The present retrospective study was undertaken to identify the major survival and nonsurvival determinants of patients who were in need of intra-aortic ballon pump support after cardiac surgery. Patients & Methods: Th...

متن کامل

Propensity matched analysis of longterm outcomes following transcatheter based aortic valve implantation versus classic aortic valve replacement in patients with previous cardiac surgery

BACKGROUND Whether minimally diseased aortic valves should be replaced during other necessary cardiac operations remains controversial. Part of the decision-making process in that issue revolves around the risks of subsequent aortic valve replacement. This study evaluated the results of aortic valve replacement in patients following prior cardiac surgery. METHODS From February, 1984 through D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015