Patient-specific quality assurance measurements for VMAT treatments: Do we really catch errors?

نویسنده

  • Charles R Thomas
چکیده

81 Background: Patient-specific quality assurance measurements are time consuming and Gamma pass/fail criteria are often picked based on typical criteria used for IMRT QA measurements in the past. The questions needs to be asked if with these criteria QA plans could still show clinically significant deviations from the treatment plan calculated and how we should be doing QA for treatment delivery of complex treatment plans. In our study DICOM files of clinical Rapidarc plans were modified with in-house developed software to mimic leaf alignment errors and gravitation shifts. The Octavius 2D-ARRAY (PTW-Freiburg) and the Delta4 device (Scandidos) were used to investigate the effect of the simulated errors on the passing rate of quality assurance results. The manipulated Rapidarc plans were recalculated on patient CT scans in Eclipse. METHODS Three different types of errors were simulated and applied to five prostate (two arcs), three 2-arc head and neck cases and three 3-arc head and neck cases. The MLC modifications were: (1) both MLC banks are opened by 0.25mm, 0.50mm and 1.00mm in opposing directions resulting in larger fields, (2) both MLC banks are closed by 0.10mm, 0.25mm and 0.50mm, (3) both MLC banks are shifted in the same direction for lateral gantry angles to simulate effects of gravitational forces onto the leaves by 1mm, 2mm and 3mm, (4) 25%, 50% 70% and 100% of all active leaves are shifted by 3mm as in (3). QA evaluations were performed according to a gamma-index criterion of 3mm and 3% as well as 2mm and 2%. RESULTS All unmodified plans and the majority of the plans with the smallest modification pass the gamma-index criterion of 2%/2mm with >90%. After that the passing rate drops below 90%. For the largest modifications passing rates were typically below 85%. The Delta4 is generally more sensitive and the passing rate for modified plans drops below 90% earlier and more drastically. With the standard criteria (3mm, 3%) even the largest modifications would satisfy a >90% passing rate. CONCLUSIONS A stricter gamma-index (2mm, 2%) is necessary in order to detect MLC positional errors and a passing rate of >90% should be expected. Clinical pass/fail criteria need to be developed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SU-F-T-311: Comparison of Measurements From Two Diode Array QA Devices to Deep Point Dose Measurements with Two Treatment Planning Model Settings for Brain VMAT SRT Patient-Specific QA.

PURPOSE To investigate the sensitivity of traditional gamma-index-based analysis using diode arrays to detect significant dosimetric errors in patientspecific measurements for VMAT brain SRT plans. METHODS Quality assurance measurements were performed using an ion chamber and two different diode array devices for four brain SRT treatment plans. All cases were planned with Eclipse AAA RapidArc...

متن کامل

The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy

In 2010, the NCS (Netherlands Commission on Radiation Dosimetry) installed a subcommittee to develop guidelines for quality assurance and control for volumetric modulated arc therapy (VMAT) treatments. The report (published in 2015) has been written by Dutch medical physicists and has therefore, inevitably, a Dutch focus. This paper is a condensed version of these guidelines, the full report in...

متن کامل

An EPID‐based system for gantry‐resolved MLC quality assurance for VMAT

Multileaf collimator (MLC) positions should be precisely and independently mea-sured as a function of gantry angle as part of a comprehensive quality assurance (QA) program for volumetric-modulated arc therapy (VMAT). It is also ideal that such a QA program has the ability to relate MLC positional accuracy to patient-specific dosimetry in order to determine the clinical significance of any dete...

متن کامل

Statistical process control analysis for patient-specific IMRT and VMAT QA

This work applied statistical process control to establish the control limits of the % gamma pass of patient-specific intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) quality assurance (QA), and to evaluate the efficiency of the QA process by using the process capability index (Cpml). A total of 278 IMRT QA plans in nasopharyngeal carcinoma were measured with ...

متن کامل

The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy.

In 2010, the NCS (Netherlands Commission on Radiation Dosimetry) installed a subcommittee to develop guidelines for quality assurance and control for volumetric modulated arc therapy (VMAT) treatments. The report (published in 2015) has been written by Dutch medical physicists and has therefore, inevitably, a Dutch focus. This paper is a condensed version of these guidelines, the full report in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical oncology : official journal of the American Society of Clinical Oncology

دوره 31 31_suppl  شماره 

صفحات  -

تاریخ انتشار 2013