Intra-irradiation changes in the signal of polymer-based dosimeter (GAFCHROMIC EBT) due to dose rate variations.
نویسندگان
چکیده
The effect of dose rate on the real-time change in optical density (DeltaOD) of a GAFCHROMIC EBT film is quantified using a previously reported optical readout approach. A range of doses (5-1000 cGy) and dose rates (16-520 cGy min(-1)) are used, and a statistically significant difference between DeltaOD of films exposed at different dose rates occurs within approximately one order of magnitude change in the dose rate. A small increase in per cent standard deviation of measured DeltaOD values is also observed when the entire dose rate range was used, but in all cases combining all DeltaOD values produces per cent standard deviation of <4.5%. Thus, whether the dose rate effect is clinically significant depends on the specific application of EBT and the desired accuracy.
منابع مشابه
Dosimetry of gamma chamber blood irradiator using Gafchromic EBT film.
Gafchromic films are increasingly being used for dosimetry in medical and industrial applications of ionizing radiation because of their favorable characteristics such as self developing in nature, easy to handle, dose rate independent response, insensitivity to normal room lights, high resolution and insensitivity to variation in the environment conditions. The dosimetry measurements using Gaf...
متن کامل(Microsoft Word - _\277\370\300\332\267\302\307\320\310\270_2009_\303\337\260\350__Evaluation of Dose Distribution using a Glass Dosimeter and a Gafchromic EBT Film in Ga)
Gamma irradiation device using Cs-137 have been widely utilized to the irradiation of cell, blood, and animal, and the dose measurement and education. The Gammacell 3000 Elan (Nordion International, Kanata, Ontario, Canada) irradiator was installed in 2003 with Cs-137 and dose rate of 3.2 Gy/min. And the BioBeam 8000 (Gamma-Service Medical GmbH, Leipzig, Germany) irradiator was installed in 200...
متن کاملThe basic radiation properties of the N-isopropylacrylamide based polymer gel dosimeter
Background: In this study the basic radiation properties of N-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. Materials and Methods: The NIPAM gel was prepared and irradiated approximately 2 h after manufacturing. The magnetic resonance (MR) images were made 24 h after irradiation. The nuclear magnetic resonance (NMR) respons...
متن کاملOptimisation of the MAGAT gel dosimeter compositions
Background: An effective polymer gel dosimeter can be fabricated by varying the composition of its chemical components. Materials and Methods: The MAGAT gel dosimeter formulations that used different compositions of Methacrylic acid (MAA) and gelatin were extensively investigated in the present study according to the R2–dose response and R2–dose sensitivity. The irradiation of M...
متن کاملCharacterization and real-time optical measurements of the ionizing radiation dose response for a new radiochromic medium.
A new radiochromic film, GafChromic EBT, was investigated for use in a real-time radiation dosimetry system. It was found to be approximately eight times more sensitive to ionizing radiation dose, exhibited less postexposure development and achieved stable readout faster than one of its predecessors, GafChromic MD-55. A clear distinction in change in optical density between exposure and postexp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physics in medicine and biology
دوره 52 22 شماره
صفحات -