Analysis of clogging in constructed wetlands using magnetic resonance.

نویسندگان

  • Robert H Morris
  • Michael I Newton
  • Paul R Knowles
  • Martin Bencsik
  • Philip A Davies
  • Paul Griffin
  • Glen McHale
چکیده

In this work we demonstrate the potential of permanent magnet based magnetic resonance sensors to monitor and assess the extent of pore clogging in water filtration systems. The performance of the sensor was tested on artificially clogged gravel substrates and on gravel bed samples from constructed wetlands used to treat wastewater. Data indicate that the spin lattice relaxation time is linearly related to the hydraulic conductivity in such systems. In addition, within biologically active filters we demonstrate the ability to determine the relative ratio of biomass to abiotic solids, a measurement which is not possible using alternative techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic resonance relaxation measurements using open- geometry sensors to assess the clog state of constructed wetlands

Monitoring the T1 relaxation of wetland clog matter has previously been identified as a gauge of its clogged state [1]. Magnetic resonance (MR) sensors explored in other work have typically been of a bore-whole configuration, which may not be ideal in a wetland environment where the sensitive volume of the sensor may become physically clogged and therefore inoperable. This work investigates two...

متن کامل

Assessment of Clogging in Constructed Wetlands

The main goal of this thesis is the assessment of the clogging degree in the horizontal subsurface flow constructed wetland of Martinlongo and Barrada WWTP, included in Algarve Multi-Municipal Sanitation System Despite of constructed wetland treatment processes being natural and constructed wetlands easy to operate, clogging phenomena can be quite complex and challenging in a way that it is nec...

متن کامل

An integrated model of substrate clogging in vertical flow constructed wetlands.

This paper presents an integrated model of substrate clogging in a vertical flow constructed wetland (VFCW). The model simulates the reduction of pore space in the wetland substrate due to combined influences of various physical, biogeochemical and plant-related processes. A series of experiments based on laboratory-scale VFCWs were conducted to examine and measure key parameters related to clo...

متن کامل

Damköhler Number Design Method to Avoid Plugging of Tidal Flow Constructed Wetlands by Heterotrophic Biofilms

Clogging of subsurface flow (SSF) treatment wetlands due to excess biofilm growth is a design problem for which only empirical guidelines exist. A method is proposed to systematically analyze this type of clogging as a design tool. In recognition of the physical reality that most SSF treatment wetland processes are a function of biofilm surface area, a Damköhler number (Da) definition based on ...

متن کامل

An integrated model of substrate clogging in vertical

18 This paper presented an integrated conceptual model to describe the substrate 19 clogging in constructed treatment wetland. The model is based on pore space 20 reduction of the wetland substrate during the integrated treatment processes including 21 physical, biological and plant-related processes. A group of laboratory scale 22 constructed wetlands (CWs) was employed to set up the experimen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 136 11  شماره 

صفحات  -

تاریخ انتشار 2011