Depth selective Mössbauer spectroscopy: Analysis and simulation of 6.4 keV and 14.4 keV spectra obtained from rocks at Gusev Crater, Mars, and layered laboratory samples

نویسندگان

  • I. Fleischer
  • G. Klingelhöfer
  • C. Schröder
  • R. V. Morris
  • M. Hahn
  • D. Rodionov
  • R. Gellert
  • P. A. de Souza
چکیده

[1] The miniaturized Mössbauer spectrometer (MIMOS) II Mössbauer spectrometers on the Mars Exploration Rovers (MER) simultaneously obtained 6.4 keV and 14.4 keV Mössbauer spectra from rock and soil targets. Because photons with lower energy have a shallower penetration depth, 6.4 keV spectra contain more mineralogical information about the near-surface region of a sample than do 14.4 keV spectra. The influence of surface layers of varying composition and thickness on Mössbauer spectra was investigated by Monte Carlo simulation and by measurement using a copy of the MER MIMOS II instrument and samples with one or two layers of known thicknesses. Thin sections of minerals or metallic Fe foil on top of a thick mineral sample were used to produce samples with thin layers of known thickness on a thick substrate. Monte Carlo simulation of MER spectra obtained on the rock Mazatzal, which displays a coating on a basaltic substrate, and other Adirondack Class rocks results in a calculated thickness of 10 mm for the Mazatzal surface layer. The 6.4 keV spectra obtained on Adirondack Class rocks, on laboratory samples, and in Monte Carlo calculations show an apparent olivine enrichment which is not related to any observable surface layer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extraterrestrial Mössbauer Spectroscopy: More than Three Years of Mars Exploration and Developments for Future Missions

The NASA Mars Exploration Rovers (MER), Spirit and Opportunity, landed on the Red Planet in January 2004. Both rovers are equipped with a miniaturized Mössbauer spectrometer MIMOS II [1]. Designed for a three months mission, both rovers and both Mössbauer instruments are still working after more than three years of exploring the Martian surface [2]. At the beginning of the mission, with a lande...

متن کامل

Laboratory Emission, Visible-near Infrared, and Mössbauer Spectroscopy of Iron Sulfates: Application to the Bright Paso Robles Soils in Gusev Crater, Mars

Introduction: The Mars Exploration Rover (MER) in Gusev Crater has exposed in its tracks an unusual occurrence of a soil high in sulfur and high in phosphorus [1, 2] at a site called Paso Robles (Fig. 1). This salty soil is thought to be composed of the following: Fe-, Mg-, and Ca-sulfates; Ca-phosphate; hematite, halite, allophane, and amorphous Si [1]. We are currently studying a large suite ...

متن کامل

Mineralogy of volcanic rocks in Gusev Crater, Mars: Reconciling Mössbauer, Alpha Particle X-Ray Spectrometer, and Miniature Thermal Emission Spectrometer spectra

[1] Complete sets of mineral abundances for relatively unaltered volcanic or volcaniclastic rocks in Gusev Crater have been determined by modeling Mössbauer subspectral areas as mineral weight percentages, and combining those percentages with the proportions of iron-free minerals not detected by Mössbauer (normative plagioclase, apatite, and chromite, as calculated from Alpha Particle X-Ray Spe...

متن کامل

Rock spectral classes observed by the Spirit Rover’s Pancam on the Gusev Crater Plains and in the Columbia Hills

[1] This paper examines the ferrous and ferric iron mineralogy of rocks inferred from 246 visible/near-infrared (430–1010 nm) multispectral observations made by the Mars Exploration Rover Spirit’s Pancam on its traverse from its landing site to its second Winter Haven location. Principal component, correspondence analyses, and a sequential maximum angle convex cone technique were used to identi...

متن کامل

Design of Light Multi-layered Shields for Use in Diagnostic Radiology and Nuclear Medicine via MCNP5 Monte Carlo Code

Introduction Lead-based shields are the most widely used attenuators in X-ray and gamma ray fields. The heavy weight, toxicity and corrosion of lead have led researchers towards the development of non-lead shields. Materials and Methods The purpose of this study was to design multi-layered shields for protection against X-rays and gamma rays in diagnostic radiology and nuclear medicine. In this...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008