Energy Efficient Design, Retrofit and Control of Evaporative Condensers in Ammonia Refrigeration Systems

نویسنده

  • Abdul Qayyum
چکیده

Ammonia refrigeration systems typically offer many energy efficiency opportunities because of their large power-draw, long runtimes and dynamic operation. Ammonia refrigeration system energy use is highly dependent upon condensing head pressure, which in turn is a function of evaporative condenser capacity and control. This paper investigates the relationship between system energy use, condenser capacity and condenser control. It begins by developing a methodology to determine condenser performance and then to simulate the annual energy use of the compressors and condenser fans. The simulation model, which uses both engineering fundamentals and empirical data, accurately captures synergistic effects between the compressors, the condenser and ambient wet-bulb temperature. Energy savings are then calculated for three cases: installing VFDs on condenser fans, using wet-bulb approach control strategy and increasing condenser performance. To illustrate the effect of climate, these simulations are performed for two different ASHRAE climate zones, Miami, FL and Minneapolis, MN, which are hot and cold climates respectively. The results show that improving the performance of an underperforming condenser is the most cost effective energy conservation measure irrespective of location. However energy savings from installing VFDs on condenser fans and utilizing wet-bulb approach strategy depends on the ambient weather conditions. Next, the internal rate of return is calculated for installing additional condenser capacity beyond standard practices in new construction applications for the same two ASHRAE climate zones. The results indicate that the internal rate of return exceeds 20% for installing twice the baseline condenser capacity. In summary, the paper presents an integrated approach for design, retrofit and control of evaporative condensers in ammonia refrigeration systems. Energy savings derived through the use of this approach can significantly improve energy efficiency of ammonia refrigeration systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Using Evaporative Condenser Instead of Air Condenser in Window-air Conditioners

In this paper,&#10 the application of evaporative cooling for refrigeration cycle to reduce power consumption in hot climates is emphasized. Experimental and analytical investigations were performed in order to specify the effect of evaporative cooling condenser instead of the commonly used air cooling condenser in window-air-conditioners. Evaporative condenser can reject more heat, thereby pre...

متن کامل

Effect of Using Evaporative Condenser Instead of Air Condenser in Window-air Conditioners

In this paper, the application of evaporative cooling for refrigeration cycle to reduce power consumption in hot climates is emphasized. Experimental and analytical investigations were performed in order to specify the effect of evaporative cooling condenser instead of the commonly used air cooling condenser in window-air-conditioners. Evaporative condenser can reject more heat, thereby preve...

متن کامل

Design and Thermodynamic analysis of solar air humidifier

In this paper, the cooling system of the air humidifire, completely powered by solar energy, has been designed and optimized. In the cooling system, instead of conventional compression cooling systems, the ammonia absorption refrigeration system has been used.Its design is done in a way that the performanceof the system has increased remarkably in environments with high temperature. The ammonia...

متن کامل

Simple Functions for Predicting Thermodynamic Properties of Ammonia-Water Mixture (RESEARCH NOTE)

The engineering calculation and simulation of absorption refrigeration systems require the availability of simple and efficient functions for the determination of thermodynamic property values of the operating fluid. This work presents a set of five simple and explicit functions for the determination of the vapor - liquid equilibrium properties of the ammonia-water mixture. The functions are co...

متن کامل

Exergoeconomic Evaluation of an Integrated Nitrogen Rejection Unit with LNG and NGL Co-Production Processes Based on the MFC and Absorbtion Refrigeration Systems

Natural gas is often associated with nitrogen and heavy compounds. The Heavy components in the natural gas not only can feed downstream units, owing to the low temperature process may be formed solid as well. Therefore, heavy components separation can be a necessity and produce useful products. Virtually, all natural gases are containing nitrogen ​​that would lower the heating value of natural ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013