Removal of Pulse Artefact from EEG Data Recorded in MR Environment at 3T. Setting of ICA Parameters for Marking Artefactual Components: Application to Resting-State Data

نویسندگان

  • Eleonora Maggioni
  • Jorge Arrubla
  • Tracy Warbrick
  • Jürgen Dammers
  • Anna M. Bianchi
  • Gianluigi Reni
  • Michela Tosetti
  • Irene Neuner
  • N. Jon Shah
چکیده

Simultaneous electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) allow for a non-invasive investigation of cerebral functions with high temporal and spatial resolution. The main challenge of such integration is the removal of the pulse artefact (PA) that affects EEG signals recorded in the magnetic resonance (MR) scanner. Often applied techniques for this purpose are Optimal Basis Set (OBS) and Independent Component Analysis (ICA). The combination of OBS and ICA is increasingly used, since it can potentially improve the correction performed by each technique separately. The present study is focused on the OBS-ICA combination and is aimed at providing the optimal ICA parameters for PA correction in resting-state EEG data, where the information of interest is not specified in latency and amplitude as in, for example, evoked potential. A comparison between two intervals for ICA calculation and four methods for marking artefactual components was performed. The performance of the methods was discussed in terms of their capability to 1) remove the artefact and 2) preserve the information of interest. The analysis included 12 subjects and two resting-state datasets for each of them. The results showed that none of the signal lengths for the ICA calculation was highly preferable to the other. Among the methods for the identification of PA-related components, the one based on the wavelets transform of each component emerged as the best compromise between the effectiveness in removing PA and the conservation of the physiological neuronal content.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Acute and Chronic Heat Exposure on Frequency of EEG Components in Different Sleep-Wake State in Young Rats

The recent literatures indicate that central nervous system (CNS) is highly vulnerable to systemic hyperthermia induced by whole body heating on conscious animals. In the present study, cerebral electrical activity or EEG (electroencephalogram) following exposure to high environmental heat has been studied in moving rats. Rats were divided into three group (i) acute heat stress-subjected to a s...

متن کامل

Simultaneous EEG/fMRI Phantom Experiments with a Realistic Neuronal Signal

Introduction: Simultaneous EEG/fMRI is hampered by large artefacts produced in the EEG signal by: (i) rapid gradient switching during fMRI acquisition, (ii) the effects of pulsatile blood flow and (iii) subject movement, the latter two of which increase linearly with field strength. One of the most prevalent correction methods for the pulse and gradient artefacts is averaged artefact subtractio...

متن کامل

A new ICA-based fingerprint method for the automatic removal of physiological artifacts from EEG recordings

Background EEG may be affected by artefacts hindering the analysis of brain signals. Data-driven methods like independent component analysis (ICA) are successful approaches to remove artefacts from the EEG. However, the ICA-based methods developed so far are often affected by limitations, such as: the need for visual inspection of the separated independent components (subjectivity problem) and,...

متن کامل

Development, validation, and comparison of ICA-based gradient artifact reduction algorithms for simultaneous EEG-spiral in/out and echo-planar fMRI recordings

EEG data acquired in an MRI scanner are heavily contaminated by gradient artifacts that can significantly compromise signal quality. We developed two new methods based on independent component analysis (ICA) for reducing gradient artifacts from spiral in-out and echo-planar pulse sequences at 3 T, and compared our algorithms with four other commonly used methods: average artifact subtraction (A...

متن کامل

EEG acquisition in ultra-high static magnetic fields up to 9.4 T

The simultaneous acquisition of electroencephalographic (EEG) and functional magnetic resonance imaging (fMRI) data has gained momentum in recent years due to the synergistic effects of the two modalities with regard to temporal and spatial resolution. Currently, only EEG-data recorded in fields of up to 7 T have been reported. We investigated the feasibility of recording EEG inside a 9.4 T sta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014