A Modified Tracer-Gas-Concentration Decay Method for Ventilation Rate Measurements in Large, Long, and Narrow Spaces

نویسندگان

  • Jiangyue Chao
  • Xuan Mu
  • Yu Xue
  • Fei Li
  • Weijuan Li
  • Chao-Hsin Lin
  • Jingjing Pei
  • Qingyan Chen
چکیده

Ventilation is essential to the health and comfort of occupants in enclosed spaces. However, it is difficult to accurately measure the ventilation rates in large, long, and narrow spaces such as aircraft cabins and train compartments. This study proposed a modified tracer-gas-concentration decay method that combined the multi-zone technique and genetic algorithm to determine ventilation rate in such spaces. To validate the proposed method, the investigation utilized both the modified decay method and the traditional decay method to numerically measure the ventilation rate in an MD-82 aircraft cabin by Computational Fluid Dynamics (CFD) technique. The results showed that the modified tracer-gas-concentration decay method can significantly improve the accuracy and reliability of the ventilation rate measurements in such a large, long, and narrow space. The modified tracer-gas-concentration decay method was also used to experimentally measure the ventilation rate in an actual MD-82 aircraft cabin. Although no exact ventilation rate could be measured, compared with the traditional tracer-gas-concentration decay method, the ventilation rate determined by the modified method was much closer to that obtained by the constant tracer-gas-concentration method, which is considered to be the most accurate measurement. .

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Contemporary and Retrospective Radon Concentration in Ramsar Dwellings Using Polycarbonate Detector

The origins of radon gas are the amount of uranium decay in the soil that is released into space and through the interior gaps of  buildings. Radon can enter the respiratory system and cause radiation hazards. Recently research has identified Radon as the second leading cause of lung cancer after cigarette smoking. The indoor concentration of Radon progeny is mentioned as an important issue reg...

متن کامل

Review and Extension of CO2-Based Methods to Determine Ventilation Rates with Application to School Classrooms

The ventilation rate (VR) is a key parameter affecting indoor environmental quality (IEQ) and the energy consumption of buildings. This paper reviews the use of CO₂ as a "natural" tracer gas for estimating VRs, focusing on applications in school classrooms. It provides details and guidance for the steady-state, build-up, decay and transient mass balance methods. An extension to the build-up met...

متن کامل

Quantification of regional ventilation in humans using a short-lived radiotracer--theoretical evaluation of the steady-state model.

The accuracy of the steady-state measurement of ventilation by means of a short-lived insoluble inert gas tracer rests with the validity of the steady-state flow equation. This has previously been applied to the qualitative assessment of regional ventilation using krypton-81m, but may potentially be used for the calculation of regional alveolar ventilation per unit alveolar gas volume--(VA/VA)c...

متن کامل

Estimation of Uncertainty in Tracer Gas Measurement of Air Change Rates

Simple and economical measurement of air change rates can be achieved with a passive-type tracer gas doser and sampler. However, this is made more complex by the fact many buildings are not a single fully mixed zone. This means many measurements are required to obtain information on ventilation conditions. In this study, we evaluated the uncertainty of tracer gas measurement of air change rate ...

متن کامل

Staff exposure rate in Mahallat hot spring region

Background: High level radiation areas have been recognized on various parts of the earth. Mahallat hot spring region is one of these areas. Study of exposure in these areas can be helpful in investigating the effects of ionizing radiation. Internal and external exposure to the staff was studied. Materials and Methods: Used materials and instruments include: RSS-112 ionizing chamber fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013