Optical/UV and X-Ray Microwave Kinetic Inductance Strip Detectors
نویسندگان
چکیده
Microwave Kinetic Inductance Detectors (MKIDs) are superconducting detectors that sense the change in the surface impedance of a thin superconducting film when Cooper Pairs are broken by using a high quality factor resonant circuit. We are developing strip detectors that have aluminum MKID sensors on both ends of a rectangular tantalum strip. These devices can provide one dimensional spatial imaging with high quantum efficiency, energy resolution, and microsecond time resolution for single photons from the IR to the X-ray. We have demonstrated X-ray strip detectors with an energy resolution of 62 eV at 6 keV, and hope to improve this substantially. We will also report on our progress towards optical arrays for a planned camera for the Palomar 200′′ telescope.
منابع مشابه
Quasiparticle Trapping in Microwave Kinetic Inductance Strip Detectors
Microwave Kinetic Inductance Detectors (MKIDs) are thin-film, superconducting resonators, which are attractive for making large detector arrays due to their natural frequency domain multiplexing at GHz frequencies. For X-ray to IR wavelengths, MKIDs can provide high-resolution energy and timing information for each incoming photon. By fabricating strip detectors consisting of a rectangular abso...
متن کاملA readout for large arrays of microwave kinetic inductance detectors.
Microwave kinetic inductance detectors (MKIDs) are superconducting detectors capable of counting single photons and measuring their energy in the UV, optical, and near-IR. MKIDs feature intrinsic frequency domain multiplexing (FDM) at microwave frequencies, allowing the construction and readout of large arrays. Due to the microwave FDM, MKIDs do not require the complex cryogenic multiplexing el...
متن کاملOptimizing diode thickness for thin-film solid state thermal neutron detectors
Related Articles Ultrafast semiconductor x-ray detector Appl. Phys. Lett. 101, 031107 (2012) X-ray bang-time and fusion reaction history at picosecond resolution using RadOptic detection Rev. Sci. Instrum. 83, 10D307 (2012) Self-powered micro-structured solid state neutron detector with very low leakage current and high efficiency Appl. Phys. Lett. 100, 243507 (2012) Position and energy-resolve...
متن کاملHigh optical efficiency and photon noise limited sensitivity of microwave kinetic inductance detectors using phase readout
kinetic inductance detectors using phase readout R. M. J. Janssen, J. J. A. Baselmans, A. Endo, L. Ferrari, S. J. C. Yates, A. M. Baryshev, and T. M. Klapwijk Kavli Institute of Nanoscience, Faculty of Applied Sciences, Delft University of Technology, Lorentzweg 1, 2628CJ Delft, The Netherlands SRON Netherlands Institute for Space Research, Sorbonnelaan 2, 3584CA Utrecht, The Netherlands SRON N...
متن کاملA WIMP Dark Matter Detector Using MKIDs
We are pursuing the development of a phononand ionization-mediated WIMP dark matter detector employing microwave kinetic inductance detectors (MKIDs) in the phonon-sensing channel. Prospective advantages over existing detectors include: improved reconstruction of the phonon signal and event position; simplified readout wiring and cold electronics; and simplified and more reliable fabrication. W...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008