Variation in the rapid shallow breathing index associated with common measurement techniques and conditions.

نویسندگان

  • Kapil N Patel
  • Kalpesh D Ganatra
  • Jason H T Bates
  • Michael P Young
چکیده

BACKGROUND The rapid-shallow-breathing index (RSBI) is widely used to evaluate mechanically ventilated patients for weaning and extubation, but it is determined in different clinical centers in a variety of ways, under conditions that are not always comparable. We hypothesized that the value of RSBI may be significantly influenced by common variations in measurement conditions and technique. METHODS Sixty patients eligible for a weaning evaluation after >or=72 hours of mechanical ventilation were studied over 15 months in a medical intensive care unit. RSBI was measured while the patients were on 2 different levels of ventilator support: 5 cm H2O continuous positive airway pressure (CPAP) versus T-piece. RSBI was also calculated in 2 different ways: using the values of minute ventilation and respiratory rate provided by the digital output of the ventilator, versus values obtained manually with a Wright spirometer. Finally, RSBI was measured at 2 different times of the day. RESULTS RSBI was significantly less when measured on 5 cm H2O CPAP, compared to T-piece: the medians and interquartile ranges were 71 (52-88) breaths/min/L versus 90 (59-137) breaths/min/L, respectively (P<.001). There were no significant differences in the value of RSBI obtained using ventilator-derived versus manual measures of the breathing pattern. RSBI was also not significantly different in the morning versus evening measurements. CONCLUSIONS RSBI can be significantly affected by the level of ventilator support, but is relatively unaffected by both the technique used to determine the breathing pattern and the time of day at which it is measured.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Role of Rapid Shallow Breathing Index in Predicting Successful Weaning of Pediatric Patients with Respiratory Failure

Background About 40 to 60% of all patients admitted to pediatric intensive care unitsundergo mechanical ventilation and 10 to 20% will fail to be extubated. We aimed to determine the role of the rapid shallow breathing index (RSBI) in predicting successful weaning of pediatric patients with respiratory failure.   Materials and Methods: This cross-sectional study, was performed on 72 mechanical...

متن کامل

Association between the rapid shallow breathing index and extubation success in patients with traumatic brain injury

OBJECTIVE To investigate the association between the rapid shallow breathing index and successful extubation in patients with traumatic brain injury. METHODS This study was a prospective study conducted in patients with traumatic brain injury of both genders who underwent mechanical ventilation for at least two days and who passed a spontaneous breathing trial. The minute volume and respirato...

متن کامل

Remifentanil improves breathing pattern and reduces inspiratory workload in tachypneic patients.

BACKGROUND Properly titrated opiates decrease respiratory rate but do not affect tidal volume or induce respiratory acidosis. OBJECTIVE To determine whether remifentanil improves breathing pattern or reduces inspiratory effort in patients with acute respiratory failure and tachypnea or rapid shallow breathing. METHODS We studied 14 patients who developed tachypnea and/or rapid shallow breat...

متن کامل

Effect of C-fiber-mediated, ozone-induced rapid shallow breathing on airway epithelial injury in rats.

We examined the relationship between C-fiber-mediated, ozone-induced rapid shallow breathing and airway epithelial cell injury at different airway sites within the lower respiratory tract of conscious Wistar rats (n = 24). We combined an acute 8-h ozone inhalation with vagal perineural capsaicin treatment, a selective C-fiber conduction block, and 5-bromo-2'-deoxyuridine (BrdU) labeling as an i...

متن کامل

Morpho-Physiological Characterization Related to Drought Tolerance of Common Bean (Phaseolus Vulgaris L.) Genotypes

Drought is one of the limiting factor in common bean, development of common bean varieties that adapted to drought situations is the main focus for improving food crops. In this study, 25 genotypes of common beans (Phaseolus vulgaris L.) were grown under drought stress and non-stress conditions. The field work was conducted at Melkassa Agricultural Research Center during the off-season that lai...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory care

دوره 54 11  شماره 

صفحات  -

تاریخ انتشار 2009