Efficacy and Safety of the Absorb Everolimus-Eluting Bioresorbable Scaffold for Treatment of Patients With Diabetes Mellitus: Results of the Absorb Diabetic Substudy.
نویسندگان
چکیده
OBJECTIVES The study sought to evaluate the efficacy and safety of the Absorb everolimus-eluting bioresorbable vascular scaffold (BVS) (Abbott Vascular, Abbott Park, Illinois) in patients with diabetes mellitus. BACKGROUND Randomized, controlled trials have demonstrated comparable clinical outcomes following percutaneous coronary intervention with either Absorb BVS or metallic Xience everolimus-eluting stent. However, these trials lack power required to provide reliable treatment effect estimates in this high-risk population. METHODS In a pre-specified, powered analysis, patients with diabetes who received ≥1 Absorb were pooled from the ABSORB II, III, and JAPAN randomized trials and from the single arm ABSORB EXTEND registry. The study composite primary endpoint was target lesion failure (TLF) at 1 year following Absorb BVS compared with a performance goal of 12.7%. RESULTS Among 754 diabetic patients included in analysis (27.3% insulin treated), the 1-year TLF rate was 8.3% (upper 1-sided 95% confidence limit: 10.1%; p = 0.0001 vs. performance goal). Scaffold thrombosis (definite or probable) was observed in 2.3% of patients. Multivariable regression identified older age, insulin treatment, and smaller pre-procedure reference vessel diameter as significant independent predictors of 1-year TLF. CONCLUSIONS The Absorb diabetic substudy suggests efficacy and safety of the Absorb BVS for treatment of patients with diabetes mellitus.
منابع مشابه
Novel 3-Dimensional Vessel and Scaffold Reconstruction Methodology for the Assessment of Strut-Level Wall Shear Stress After Deployment of Bioresorbable Vascular Scaffolds From the ABSORB III Imaging Substudy.
A 72-year-old female patient underwent successful deployment of a single 3.0 18 mm Absorb bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, California) to the mid right coronary artery (Figures 1A and 1B). The scaffolded segment was imaged simultaneously with coronary angiography and with the C7 Dragonfly (LightLab Imaging Inc., St. Jude Medical, Westford, Massachusetts) optical co...
متن کاملEconomic Outcomes of Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention: 1-Year Results From the ABSORB III Trial.
OBJECTIVES The purpose of this study was to evaluate the economic impact of the Absorb bioresorbable vascular scaffold compared with the Xience everolimus-eluting stent in patients undergoing percutaneous coronary intervention. BACKGROUND The ABSORB III trial (Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease) demonstrated that the Absorb scaffold was noninferior to the X...
متن کاملBioresorbable Vascular Scaffolds Versus Metallic Stents in Patients With Coronary Artery Disease: ABSORB China Trial.
BACKGROUND The everolimus-eluting bioresorbable vascular scaffold (BVS) is designed to achieve results comparable to metallic drug-eluting stents at 1 year, with improved long-term outcomes. Whether the 1-year clinical and angiographic results of BVS are noninferior to current-generation drug-eluting stents has not been established. OBJECTIVES This study sought to evaluate the angiographic ef...
متن کاملThree-Year Outcomes With the Absorb Bioresorbable Scaffold: Individual-Patient-Data Meta-Analysis From the ABSORB Randomized Trials.
BACKGROUND The Absorb bioresorbable vascular scaffold (BVS) completely resorbs within 3 years after coronary artery implantation. The safety and effectiveness of BVS through this critical 3-year period have not been characterized. METHODS We performed an individual-patient-data pooled meta-analysis of the 4 randomized ABSORB trials in which 3389 patients with coronary artery disease were rand...
متن کاملEverolimus-eluting bioresorbable vascular scaffold in daily clinical practice: A single-centre experience
BACKGROUND Recent evidence has raised concerns regarding the safety of the everolimus-eluting bioresorbable vascular scaffold (E-BVS) (Absorb, Abbott Vascular, Santa Clara, CA, USA). Following these data, the use of this device has diminished in the Netherlands; however, daily practice data are limited. Therefore we studied the incidence of safety and efficacy outcomes with this device in daily...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JACC. Cardiovascular interventions
دوره 10 1 شماره
صفحات -
تاریخ انتشار 2017