Automated patient motion detection and correction in dynamic renal scintigraphy.
نویسندگان
چکیده
UNLABELLED Kidney motion during dynamic renal scintigraphy can cause errors in calculated renal function parameters. Our goal was to develop and validate algorithms to detect and correct patient motion. METHODS We retrospectively collected dynamic images from 86 clinical renal studies (42 women, 44 men), acquired using (99m)Tc-mercaptoacetyltriglycine (80 image frames [128 × 128 pixels; 3.2 mm/pixel]: twenty-four 2-s frames, sixteen 15-s frames, and forty 30-s frames). We simulated 10 types of vertical motion in each patient study, resulting in 860 image sets. Motion consisted of up or down shifts of magnitude 0.25 pixel to 4 pixels per frame and was either a gradual shift additive over multiple frames or an abrupt shift of one or more consecutive frames, with a later return to the start position. Additional horizontal motion was added to test its effect on detection of vertical motion. Original and shifted files were processed using a motion detection algorithm. Corrective shifts were applied, and the corrected and original (unshifted) images were compared pixel by pixel. Motion detected in the shifted data was also tabulated before and after correction of motion detected in the original data. A detected shift was considered correct if it was within 0.25 pixel of the simulated magnitude. Software was developed to facilitate visual review of all images and to summarize kidney motion and motion correction using linograms. RESULTS Overall detection of simulated shifts was 99% (3,068/3,096 frames) when the existing motion in the original images was first corrected. When the original motion was not corrected, overall shift detection was 76% (2,345/3,096 frames). For image frames in which no shift was added (and original motion was not corrected), 87% (27,142/31,132 frames) were correctly detected as having no shift. When corrected images were compared with original images, calculated count recovery was 100% for all shifts that were whole-pixel magnitudes. For fractional-pixel shifts, percentage count recovery varied from 52% to 73%. Visual review suggested that some original frames exhibited true patient motion. CONCLUSION The algorithm accurately detected motion as small as 0.25 pixel. Whole-pixel motion can be detected and corrected with high accuracy. Fractional-pixel motion can be detected and corrected, but with less accuracy. Importantly, by accurately identifying unshifted frames, the algorithm helps to prevent the introduction of errors during motion correction.
منابع مشابه
Early detection of renal scarring in children with suspected pyelonephritis: Comparison of diuretic MAG3 scintigraphy (F0) and DMSAScan
Abstract Background: Screening for patients at risk of renal scarring is a challenge in children with acute pyelonephritis (APN). Diuretic Tc-99m mercaptoacetyltriglycine (MAG3) scintigraphy with zero time injection of furosemide (MAG3-F0) was observed to display focal parenchymal disorders. The advantages of MAG3 include: lower radiation dose and short duration of the test. The aim of this st...
متن کاملAdvanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
متن کاملاصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدلسازی منحنی چند جمله ای
Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...
متن کاملDetection of solitary bone metastasis by 99mTc-octreotide scintigraphy in a patient with Hurthle cell carcinoma: A case report
A 75-year-old male patient with non-avid radioiodine Hurthle cell carcinoma was evaluated by 99m Tc- octreotide scintigraphy, in order to find possible metastatic lesions. A bony metastatic lesion was detected by this procedure which was confirmed by histopathology.99mTc-octreotide scintigraphy is a precise and cost-effective imaging modality for detection of non-iodine av...
متن کاملuse of 99m Tc-DMSA scintigraphy in assessment of renal complications of COVID-19
ABSTRACT COVID-19 mainly affects respiratory and immune systems, but other organs like renal, cardiovascular, lung and nervous systems could also be involved in both acute and chronic settings (1, 2). There is a lot of studies that demonstrate an increasing number of long COVID-19 who continue to experience persistent symptoms weeks or even months after the initial disease. Reports suggest...