Differential phase contrast with a segmented detector in a scanning X-ray microprobe.
نویسندگان
چکیده
Scanning X-ray microprobes are unique tools for the nanoscale investigation of specimens from the life, environmental, materials and other fields of sciences. Typically they utilize absorption and fluorescence as contrast mechanisms. Phase contrast is a complementary technique that can provide strong contrast with reduced radiation dose for weakly absorbing structures in the multi-keV range. In this paper the development of a segmented charge-integrating silicon detector which provides simultaneous absorption and differential phase contrast is reported. The detector can be used together with a fluorescence detector for the simultaneous acquisition of transmission and fluorescence data. It can be used over a wide range of photon energies, photon rates and exposure times at third-generation synchrotron radiation sources, and is currently operating at two beamlines at the Advanced Photon Source. Images obtained at around 2 keV and 10 keV demonstrate the superiority of phase contrast over absorption for specimens composed of light elements.
منابع مشابه
Fast Differential Phase-Contrast Imaging and Total Fluorescence Yield Mapping in a Hard X-ray Fluorescence Microprobe
We have incorporated differential phase-contrast (DPC) detection in a hard x-ray fluorescence microprobe at the Advanced Photon Source. We report a straightforward implementation of unidirectional DPC and demonstrate that it is highly advantageous for imaging low-Z specimens with hard x-rays (10keV). Phase-contrast imaging of a specimen can be used to acquire fast overview images of samples tha...
متن کاملQuantitative amplitude and phase contrast imaging in a scanning transmission X-ray microscope.
Phase contrast in X-ray imaging provides lower radiation dose, and dramatically higher contrast at multi-keV photon energies when compared with absorption contrast. We describe here the use of a segmented detector in a scanning transmission X-ray microscope to collect partially coherent bright field images. We have adapted a Fourier filter reconstruction technique developed by McCallum, Landaue...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملTwo-dimensional micromechanical bimorph arrays for detection of thermal radiation
Related Articles Comment on “The long range voice coil atomic force microscope” [Rev. Sci. Instrum. 83, 023705 (2012)] Rev. Sci. Instrum. 83, 097103 (2012) Femtosecond pump/supercontinuum-probe setup with 20 kHz repetition rate Rev. Sci. Instrum. 83, 093105 (2012) Velocity map photoelectron-photoion coincidence imaging on a single detector Rev. Sci. Instrum. 83, 093103 (2012) Crosstalk in x-ray...
متن کاملSynthesis and characterization of Gd2O2 S: Tb3+ phosphor powder for X-ray imaging detectors
Gadolinium oxysulfide phosphor doped with trivalent terbium have been synthesized using urea homogenous precipitation and followed by sulfurization at 800 °C under argon atmosphere. Structural and morphological of synthesized phosphor powder were characterized by x-ray diffraction (XRD), scanning electron microscopy (SEM) and Fourier transform infrared spectrometry (FT-IR). Hexagonal structure ...