Azimuthal Sorting in Tandem with Elliptical Reordering (ASTER): a new k-space reordering scheme for reduced motion sensitivity

نویسندگان

  • M. Saranathan
  • E. Bayram
  • A. Madhuranthakam
چکیده

Purpose: MRI is very sensitive to motion, particularly in 3D imaging where temporally localized motion can propagate across the whole reconstructed volume. In cardiac and abdominal imaging applications, subjects are required to suspend their respiration for a period of 15-25s to minimize ghosting and blurring artifacts. Breathholding poses difficulties in pediatric and elderly subjects and in patients with severe health conditions. Even in regions where breath-holding is not required (e.g. the brain, spine, and joints), involuntary motion is quite common especially towards the end of a long scan. We propose ASTER (Azimuthal Sorting in Tandem with Elliptical Reordering), a novel k-space reordering scheme that minimizes sensitivity to motion whilst permitting flexible combination with magnetization preparation schemes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation Tool for k-Space Reordering in Free-Breathing Navigator-Gated 3D Coronary MRA

In coronary MR angiography (MRA) breathing motion during data acquisition may result in image artifacts. One solution is the use of MR navigators to gate to the respiratory cycle, but the use of narrow gating windows often lead to prolonged/time inefficient scans. Therefore sophisticated k-space reordering techniques 1, 2 have been proposed to reduce motion artifacts in free-breathing navigator...

متن کامل

Comparison of respiratory motion suppression techniques for 4D flow MRI.

PURPOSE The purpose of this work was to assess the impact of respiratory motion and to compare methods for suppression of respiratory motion artifacts in 4D Flow MRI. METHODS A numerical 3D aorta phantom was designed based on an aorta velocity field obtained by computational fluid mechanics. Motion-distorted 4D Flow MRI measurements were simulated and several different motion-suppression tech...

متن کامل

Navigator-based Elliptical k-Space Reordering for Aortic 4D-Flow Imaging

Figure 3 (right) – Comparison of ky-onlyand ky-kz-reordered scans with 100% data acceptance and with a 4mm navigator window. Figure 1 (above) – Diagram illustrating the radial reordering process. Vertical axis is ky, horizontal axis is kz and color represents calculated radius in the top part of the figure. The bottom part of the figure shows the navigator signal and the respiratory gating wind...

متن کامل

The shifted radial reordering for intermediate TE imaging in 3D long echo train acquisition

Introduction Use of nonselective pulses and modulated flip angles (aka SPACE, [2, 3, 4]) in refocusing pulses improves the sampling efficiency in 3D turbo spin echo imaging. Two flexible reordering schemes, the linear mode and the radial mode, have been proposed [1] to circumvent some intrinsic limitations of the rectangular kspace sampling grid (e.g., allowing for flexible k-space coverage) in...

متن کامل

Selective Block-Wise Reordering Technique for Very Low Bit-Rate Wavelet Video Coding∗

In this paper, we present a novel energy compaction method, called the selective block-wise reordering, which is used with SPIHT (SBR-SPIHT) coding for low rate video coding to enhance the coding efficiency for motion-compensated residuals. In the proposed coding system, the motion estimation and motion compensation schemes of H.263 are used to reduce the temporal redundancy. The residuals are ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008