Measurement of Changes in Tissue Metabolism Using a Clark-type Oxygen Sensor

نویسندگان

  • Benjamin Franc
  • Nathalia Peixoto
  • Laurent Giovangrandi
  • Glen McLaughlin
  • Gregory T.A. Kovacs
چکیده

This paper presents data characterizing the ability to measure metabolic activity at a tissue interface using a Clark-type oxygen concentration sensor consisting of a microfabricated thinfilm electrode matrix overlaid with a solid-state proton conductive matrix and encapsulated in a bio-inert polytetrafluoroethylene film. HL-1 atrial myocytes were cultured onto the sensor surface. Cyclic voltammetry was utilized to characterize the sensor response over 30 minutes while the overlying tissue was subjected to either triiodothyronine or verapamil, drugs known to upregulate or downregulate, respectively, the metabolic activity of myocardial cells. Levels of percent of baseline current were calculated for both drugs, as well as for controls. The change of measured oxygen concentration was considered inversely proportional to the change in metabolic activity. Each of the drugs exerted a significant metabolic effect on the tissue, as evidenced by changes in the sensor current, thus confirming the ability to measure cellular metabolic changes at the tissue surface using the Clark-type oxygen sensor. Verapamil at 25μg/L was found to increase oxygen concentration to 135±4% as compared to control values (95±8%). Triiodothyronine at 2.5μg/L, on the other hand, decreased oxygen levels in the extracellular space to 85±9%, as compared to baseline oxygen (98±6%). The recorded metabolic effects of the tested drugs were consistent with their known physiologic effects. This sensor has possible applications in drug screening or toxicological detection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potential errors in conventional DOT measurement techniques in shake flasks and verification using a rotating flexitube optical sensor

BACKGROUND Dissolved oxygen tension (DOT) is an important parameter for evaluating a bioprocess. Conventional means to measure DOT in shake flasks using fixed Clark-type electrodes immersed in the bulk liquid are problematic, because they inherently alter the hydrodynamics of the systems. Other approaches to measure DOT that apply fluorescing sensor spots fixed at the inside wall of a shake fla...

متن کامل

Characterization of an O2 Sensor Using Microelectrodes

This paper describes the response characteristics of a Clark type oxygen sensor using microelectrodes under a variety of operating conditions. The silicon based microelectrodes were fabricated using a CMOS process with Pt surface using a lift-off process. The Clark type sensor was configured using a threeelectrode system. A set of four operating conditions with varying activation voltages, the ...

متن کامل

تخمین خروجی سنسور اکسیژن غیرخطی بعد از کاتالیست با استفاده از شبکه NARX

Great effect of three way catalytic convertor (TWC) performance on oxygen sensor output voltage has made the sensor (located after catalyst) as the main signal in almost all today’s TWC monitoring algorithms. In this paper output voltage of nonlinear oxygen sensor is estimated using a nonlinear autoregressive with exogenous inputs (NARX) model. The estimation uses ECU calculated exhaust gas flo...

متن کامل

Fabrication of miniature Clark oxygen sensor integrated with microstructure

A miniature Clark-type oxygen sensor has been integrated with a microstructure using a novel fabrication technique. The oxygen chip consists of a glass substrate with a three-electrode configuration, which is separated and connected by a groove, and a poly(dimethylsiloxane) (PDMS) container with an immobilized PDMS oxygen-permeable membrane. The assembly of the different substrates only uses th...

متن کامل

Oil Quality Monitoring in Gasoline Spark Ignition Engine Using Oil Dielectric Measurement

Oil analysis is one of the main methods for monitoring the status of internal combustion engines and oils to ensure the lubricant's protective performance and engine health. This paper investigate oil condition monitoring in gasoline engine using oil dielectric coefficient measurement. At first capacitive sensor pectinate type is designed and manufactured that engine oil can pass through the se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002