Serial assessment by optical coherence tomography of early and late vascular responses after implantation of an absorbable-coating Sirolimus-Eluting stent (from the first-in-human DESSOLVE I trial).
نویسندگان
چکیده
The initial enthusiasm caused by the potent antirestenotic effect of early generation drug-eluting stents was recently plagued by concerns regarding their safety profile. Investigators worldwide were stimulated, therefore, to seek for improvement in drug-eluting stent technology, such as eliminating their permanent polymer blamed for vascular inflammation and delayed healing. Optical coherence tomography (OCT) assessments of stent-vessel interactions are used as a surrogate for vessel healing after DES implantation. Herewith, we report serial OCT assessments of vascular reactions to the implantation of a novel absorbable polymer sirolimus-eluting stent (MiStent). In total, 30 patients were included. At 4-, 6-, and 8-month follow-up, different groups of 10 patients underwent OCT imaging, whereas all the patients had OCT assessments scheduled at 18-month follow-up. A total of 13,569 stent struts were analyzed. Low rates of uncovered (14.34 ± 15.35%, 6.62 ± 10.93%, 3.51 ± 2.87%, and 0.84 ± 1.15%, respectively, p <0.05 for 8- vs 18-month follow-up) and malapposed (3.74 ± 7.35%, 3.15 ± 6.13%, 0.48 ± 0.56%, and 0.09 ± 0.28%, respectively, p = NS) stent struts coupled with thin and increasingly homogenous neointimal proliferation were demonstrated. Neointimal area increased from 4- to 8-month follow-up (0.46 ± 0.29 and 1.12 ± 0.73 mm(2), respectively, p <0.05), whereas no "late catch up" was demonstrated at 18-month follow-up (1.28 ± 0.66 mm(2), p = NS vs 8-month follow-up). Early tissue maturation and reduction of low signal intensity tissue covering stent struts (8.8%, 3.1%, 0.3%, and 0%, respectively, p <0.05 for 4- vs 8-month follow-up comparison) were revealed by optical density analysis. In addition, high rates of strut coverage overlying the ostia of side branches without proliferative pattern were demonstrated. In conclusion, this comprehensive OCT analysis depicted favorable absorbable polymer sirolimus-eluting stent-vessel interactions up to 18-month follow-up.
منابع مشابه
Late vascular responses from 2 to 4 years after implantation of sirolimus-eluting stents: serial observations by intracoronary optical coherence tomography.
BACKGROUND Late vascular responses after implantation of drug-eluting stents may play a key role in steadily increasing occurrence of very late stent thrombosis have not yet been fully investigated in human beings. METHODS AND RESULTS Serial optical coherence tomography observations at 2 and 4 years were collected for 17 patients treated with 21 sirolimus-eluting stents. Corresponding 376 cro...
متن کاملRandomised study of a bioabsorbable polymer-coated sirolimus-eluting stent: results of the DESSOLVE II trial.
AIMS To compare the efficacy and safety of the MiStent absorbable polymer sirolimus-eluting stent (APSES) with a zotarolimus-eluting stent (ZES). METHODS AND RESULTS The trial was a 2:1 randomisation at 26 sites of 184 patients implanted with an APSES (n=123) versus a ZES (n=61). Following stent implantation, all patients underwent quantitative coronary angiography at baseline and at nine mon...
متن کاملEvaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial.
OBJECTIVES We performed this study to investigate the vascular response in early period after zotarolimus-eluting stent (ZES) (Endeavor Sprint, Medtronic CardioVascular, Minneapolis, Minnesota) implantation. BACKGROUND The ZES has different characteristics, with biocompatible polymer and rapid drug-elution, compared with the first-generation drug-eluting stents (DES). METHODS The ENDEAVOR O...
متن کاملSerial observation of drug-eluting absorbable metal scaffold: multi-imaging modality assessment.
BACKGROUND The drug-eluting absorbable metal scaffold has demonstrated feasibility, safety, and promising clinical and angiographic outcomes at 12 months in human coronary arteries. This study aimed to evaluate the degradation rate and long-term vascular responses to drug-eluting absorbable metal scaffold. METHODS AND RESULTS BIOSOLVE-I was a multicenter, single-arm, first-in-man trial assess...
متن کاملMechanisms of very late stent thrombosis after drug-eluting stent implantation: findings from coronary angioscopy and optical coherence tomography.
D R U G E L U T I N G S T E N T S ( D E S ) A R E N O W W I D E L Y U S E D F O R P A T I E N T S W I T H C O R O N A R Y A R T E R Y D I S E A S E U N D E R G O I N G P E R C U T A N E O U S C O R O N A R Y I N T E R V E N T I O N S . A current major concern of using DES is very late stent thrombosis (VLST) that may occur beyond 1 year after DES implantation (1). VLST is an infrequent, albeit ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The American journal of cardiology
دوره 112 10 شماره
صفحات -
تاریخ انتشار 2013