BACKGROUND AND PURPOSE While the number of CTA examinations is continually increasing compared with DSA examinations, there is little comparative dose information about the different imaging techniques. We compared patient radiation exposure resulting from diagnostic CTA and DSA examinations for both cerebral and cervicocerebral vessels. MATERIALS AND METHODS An anthropomorphic phantom was irradiated by using typical diagnostic CTA and DSA setups and imaging parameters. For both imaging techniques, the imaging area of cerebral vessels included intracranial vessels only, while the imaging area of cervicocerebral vessels included both cervical and intracranial vessels from the aortic arch to the vertex. The effective dose was determined by using RPLDs. The DSA examination was simulated by using a biplane angiography system, and the CTA examination, by using a 64-row multidetector CT scanner. RESULTS For the imaging of cerebral vessels, the effective dose according to ICRP 103 was 0.67 mSv for CTA and 2.71 mSv for DSA. For the imaging of cervicocerebral vessels, the effective dose was 4.85 mSv for CTA and 3.60 mSv for DSA. The maximum absorbed dose (milligray) for skin, brain, salivary glands, and eyes was 166.2, 73.5, 35.6, and 21.8 mGy for DSA and 19.0, 16.9, 20.4, and 14.8 mGy for CTA, respectively. The conversion factors from DAP and DLP to effective dose were calculated. CONCLUSIONS The effective dose for CTA assessment of cerebral vessels was approximately one-fifth the dose compared with DSA. In the imaging of cervicocerebral vessels, the effective dose for CTA was approximately one-third higher compared with DSA.
منابع مشابه
Assessment of radiation-induced cancer risk to patients undergoing computed tomography angiography scans
Background: Computed tomography angiography (CTA) scan is a suitable imaging technique to evaluate the blood vessels. However, one major disadvantage is the potential risk of cancer related to ionizing radiation exposure during the procedures. The aim of this investigation was to estimate the risk of exposure induced cancer death (REID) values for some common computed tomography angiography (CT...
متن کاملClinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography
Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified les...
متن کاملRadiation exposure of patients in comprehensive computed tomography of the head in acute stroke.
BACKGROUND AND PURPOSE To assess patient radiation exposure in comprehensive stroke imaging using multidetector row CT (MDCT) combining standard CT of the head, cerebral perfusion (CTP), and CT angiography (CTA) studies. METHODS Examination protocols for CT and CTA of cerebral and cervical vessels, as well as CTP were simulated using a Somatom Sensation Cardiac 64. Effective doses were derive...
متن کاملRadiation exposure from conventional and digital subtraction angiography of cerebral vessels.
Patients with atherosclerotic cerebrovascular disease were studied to determine the radiation exposure associated with conventional and digital subtraction angiography of the cerebral vessels. The median exposure-area product was 3198 R cm2 (range, 616-5665 R cm2) in the conventional angiography group and 1831 R cm2 (range, 366-4198 R cm2) in the IV digital subtraction angiography (DSA) group. ...
متن کاملSpiral CT angiography in diagnosis of cerebral aneurysms of cases with acute subarachnoid hemorrhage.
PURPOSE To investigate the diagnostic accuracy of spiral CT angiography (CTA) in detection of cerebral aneurysms in cases with acute subarachnoid hemorrhage (SAH). MATERIALS AND METHODS Spiral CT angiography and DSA examinations were performed in 32 cases due to non-traumatic SAH. CTA data were obtained by maximum intensity projection (MIP) method. CTA and DSA findings were evaluated and comp...