Eleven peak flow meters: a clinical evaluation.

نویسندگان

  • H Folgering
  • W vd Brink
  • O v Heeswijk
  • C v Herwaarden
چکیده

Peak flow meters are essential tools in the management of asthma. Many types are on the market. A computer-driven piston pump is normally not available for evaluation of the various meters. Comparison with values from a pneumotachograph is an accepted way of testing peak flow meters. This study aims at comparing 11 peak flow meters, for accuracy and linearity. Seven adult peak flow meters were tested: Miniwright with an equidistant scale (Clement Clarke); Personal Best (Healthscan); Wright Pocket fdE (Ferraris); Vitalograph (Vitalograph); Assess (Healthscan); Pocket Peak flow meter (Micro Medical); and Truzone (Monaghan). Furthermore, four low-range (LR) peak flow meters were tested: LR Miniwright with equidistant scale (Clement Clarke); LR Personal Best (Healthscan); LR Wright Pocket (LR Ferraris); and LR Pocket peak flow meter (LR Micro Medical). Two test series were performed: in the first one, a peak flow meter was connected downstream in series with a Fleisch #4 pneumotachograph. One subject performed 50 partial forced expiratory manoeuvres through this ensemble. In the second series, 50 adult patients and 25 healthy children performed sequential maximal forced expiratory manoeuvres on each peak flow meter, and on the pneumotachograph. A ranking system was devised for the various parameters of agreement of the meters with the pneumotachograph. Substantial differences in the quality of the adult meters were found. The adult peak flow meters with the closest agreement to the pneumotachograph were Personal Best and Micro Medical. In the low-range peak flow meters, the lowest differences were seen in the LR Personal Best and LR Micro Medical.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration of some Wright peak flow meters.

The performance of Wright peak flow meters is described using an absolute and precise calibration method. This showed errors as great as 25% with the peak flow meter and 40% with the mini peak flow meter. At large flow rates errors were less. The expected variation between individual peak flow meters was about 12%. The expected variation between individual mini peak flow meters was between 16% ...

متن کامل

Peak expiratory flow at increased barometric pressure: comparison of peak flow meters and volumetric spirometer.

Increasing numbers of patients are receiving hyperbaric oxygen therapy as an intensive care treatment, some of whom have pre-existing airway obstruction. Spirometers are the ideal instruments for measuring airway obstruction, but peak flow meters are useful and versatile devices. The behaviour of both types of device was therefore studied in a hyperbaric unit under conditions of increased press...

متن کامل

Portable peak flow meters: physical characteristics, influence of temperature, altitude, and humidity.

Little is known about the linearity of portable peak flow meters, or about physical gas factors affecting peak expiratory flow (PEF) readings. We therefore tested five portable peak flow meters of three types in an altitude chamber (sea level to 5,500 m) and in a climate chamber at sea level (7-37 degrees C) to determine the influence of the physical conditions of the gas on the reading of the ...

متن کامل

Peak expiratory flow: conclusions and recommendations of a Working Party of the European Respiratory Society.

The use of peak flow meters has been widely adopted for monitoring patients with asthma. The Working Party of the European Respiratory Society (ERS) has solely addressed technical and physiological issues relating to peak expiratory flow (PEF) (flow describes the rate of change of volume (volume rate), so that flow rate is equivalent to volume acceleration. Hence, PEF should be used in preferen...

متن کامل

Frequency response of variable orifice type peak flow meters: requirements and testing.

Little is known about the response of variable orifice peak flow meters to high frequency flow input. The purpose of this study was to define and test dynamic requirements for such peak flow meters. In a population sample we measured peak expiratory flow (PEF), rise time (tr), from 10-90% PEF and the duration of the flow in excess of 97.5, 95 and 90% of PEF, by use of a carefully calibrated Fle...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 1998