PURPOSE We investigated factors predictive of false-negative pulmonary lesions with nonspecific benign cytology results on percutaneous transthoracic fine-needle aspiration biopsy (FNAB). MATERIALS AND METHODS We included 222 pulmonary lesions that had a nonspecific benign result from percutaneous transthoracic FNAB between March 2005 and December 2012, and were confirmed by subsequent pathologic results or adequate clinical follow up over at least 2 years. Clinical, imaging, and biopsy procedure-related findings were compared between lesions with a final diagnosis of malignancy (false-negative) and lesions with a benign diagnosis (true-negative). Multivariate logistic regression analysis was performed to identify significant predictors of false-negatives. RESULTS Of 222 lesions, 115 lesions were proved to be false-negatives, and 107 were true-negatives. Compared with the true-negatives, false-negative lesions showed significantly older age (p=0.037), higher maximum standardized uptake value (SUVmax) on positron emission tomography (p=0.001), larger lesion size (p=0.007), and lesion characteristics of a subsolid nodule (p=0.007). On multivariate logistic regression analysis, SUVmax, lesion size, and lesion characteristics were significant predictors of false-negative results. CONCLUSION Among the clinical, radiologic, and procedure-related factors analyzed, high SUVmax, large lesion size, and subsolid lesions were useful for predicting malignancy in pulmonary lesions with nonspecific benign cytology results on FNAB.
منابع مشابه
PERCUTANEOUS TRANSTHORACIC BIOPSY USING TRU-CUT NEEDLE
Biopsies of thoracic lesions guidance. 22 of the 1 12 lesions were mediastinal and 83 were pleuroparenchymal. A large-bore 14-gauge Tru-cut needle was used in all patients. Adequate specimens for histologic examination were obtained in 98%. The overall accuracy was 91 % with 9% false negative and no false positive diagnoses. Despite the large size of the needle, the total number of complic...
متن کاملTHE DIAGNOSTIC VALUE OF FINE NEEDLE ASPIRATION BIOPSY OF HEAD AND NECK MASSES
In an attempt to determine the diagnostic value of FNA biopsy of head and neck masses, we reviewed FNAs performed on target lesions of the head and neck in1 59 patients who subsequently underwent surgery in Khalili hospital dur-. ing a 55 month period. Results ofFNAs were compared with postsurgical histologic diagnoses. These 159 cases were broken down into four categories: thyroid masses ...
متن کاملCT-guided percutaneous transthoracic needle biopsy of lung lesions – 2-year experience at the Institute of Radiology in Ljubljana
Background. In 1883, Leyden described percutaneous lung biopsy, but it was not until 1970s that image guided fine needle chest biopsy gained widespread acceptance. Haaga and Alfidi reported CT-guided thoracic biopsy in 1976. Currently, tissue sampling of a thoracic lesion is indicated when the diagnosis is not obtained by the endobronchial technique and when the cytological diagnosis will modif...
متن کاملCT-guided transthoracic biopsy: histopathologic results and complication rates.
PURPOSE We aimed to investigate the effectiveness and complications of transthoracic CT-guided biopsy techniques. METHODS A total of 94 CT-guided percutaneous transthoracic biopsy procedures performed in 85 patients were retrospectively evaluated. Core biopsy technique was used in 87 procedures and transthoracic fine-needle aspiration biopsy was used in seven procedures. RESULTS Diagnostic ...
متن کاملارزیابی کارآیی آسپیراسیون سوزنی پستان در تشخیص زودرس سرطان پستان
Fine-needle aspiration biopsy for the diagnosis of breast lesions has been used for more than six decades and has been established as an effective procedure in Europe for many years. In order to evaluate the accuracy of fine-needle aspiration with histopathologic confirmation, a retrospective study was performed in Iranian Center for Breast Cancer, using a computer database over one year period...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 57 شماره