Snapshot voltammetry using a triangular bipolar microelectrode.

نویسندگان

  • Byoung-Yong Chang
  • François Mavré
  • Kwok-Fan Chow
  • John A Crooks
  • Richard M Crooks
چکیده

In this paper, we report a new electroanalytical technique we call snapshot voltammetry. This method combines the properties of bipolar electrodes with electrogenerated chemiluminescence (ECL) to provide a means for recording optical voltammograms in a single micrograph. In essence, the information in a snapshot voltammogram is contained in the spatial domain rather than in the time domain, which is the case for conventional voltammetry. The use of a triangle-shaped bipolar electrode stabilizes the interfacial potential difference along its length. Basic electrochemical parameters extracted from snapshot voltammograms are in good agreement with those obtained by conventional voltammetry. Although not explicitly demonstrated in this paper, this method offers the possibility of using arrays of bipolar electrodes to obtain numerous snapshot voltammograms simultaneously.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Steady-state voltammetry of a microelectrode in a closed bipolar cell.

Here we report the theory and experimental study of the steady-state voltammetric behavior of a microelectrode used as a limiting pole in a closed bipolar electrochemical cell. We show that the steady-state voltammetric response of a microelectrode used in a closed bipolar cell can be quantitatively understood by considering the responses of both poles in their respective conventional two-elect...

متن کامل

Electrochemical oxidation mechanism of guanine and adenine using a glassy carbon microelectrode.

The electrochemical oxidation mechanism of guanine and adenine was investigated using a glassy carbon microelectrode and cyclic and differential pulse voltammetry. It is pH-dependent and the electron transfer process occurs in consecutive steps with the formation of strongly adsorbed dimers on the electrode surface for both compounds.

متن کامل

Detection of Toxic Heavy Metal, Co(II) Trace via Voltammetry with Semiconductor Microelectrodes

The cobalt (Co(II)) ion is a main component of alloys and considered to be carcinogenic, especially due to the carcinogenic and toxicological effects in the aquatic environment. The toxic trace of the Co(II) detection was conducted using the infrared photodiode electrode (IPDE) using a working electrode, via the cyclic and square-wave anodic stripping voltammetry. The results indicated a sensit...

متن کامل

Voltammetry in solutions of low ionic strength. Electrochemical and analytical aspects

Recent progress in microelectrode voltammetry in solutions without or with low concentrations of supporting electrolyte is reviewed. The following points are addressed: mathematical treatment of transport, experimental setup, steady state and non steady state transport, migration coupled with homogeneous equilibrium, voltammetry in undiluted redox liquids, studies on the mechanism of the electr...

متن کامل

Differential linear scan voltammetry: analytical performance in comparison with pulsed voltammetry techniques.

We report here on differential linear scan voltammetry, DLSV, that combines the working principles of linear scan voltammetry, LSV, and the numerous existing pulsed voltammetry techniques. DLSV preserves the information from continuous interrogation in voltage and high accuracy that LSV provides about electrochemical processes, and the much better sensitivity of differential pulsed techniques. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 82 12  شماره 

صفحات  -

تاریخ انتشار 2010