Objective Assessment of Nuclear and Cortical Cataracts through Scheimpflug Images: Agreement with the LOCS III Scale

نویسندگان

  • Alberto Domínguez-Vicent
  • Ulrika Birkeldh
  • Laurell Carl-Gustaf
  • Maria Nilson
  • Rune Brautaset
  • Kristin J. Al-Ghoul
چکیده

PURPOSE To assess nuclear and cortical opacities through the objective analysis of Scheimpflug images, and to check the correlation with the Lens Opacity Classification System III (LOCS III). METHODS Nuclear and cortical opacities were graded according to the LOCS III rules after pupil dilation. The maximum and average pixel intensity values along an elliptical mask within the lens nucleus were taken to analyse nuclear cataracts. A new metric based on the percentage of opaque pixels within a region of interest was used to analyse cortical cataracts. The percentage of opaque pixels was also calculated for half, third and quarter areas from the region of interest's periphery. RESULTS The maximum and average intensity values along the nucleus were directly proportional to the LOCS III grade: The larger the LOCS III value, the larger maximum and average intensity ones. These metrics showed a positive and significant correlation with the LOCS grade: The larger the LOCS grade, the higher was percentage of opaque pixels along the cortex within the same mask's size. This metric showed a significant correlation to the LOCS grade. CONCLUSION The metrics used to assess nuclear opacities showed good correlation with the LOCS III. The percentage of opaque pixels showed to be a useful metric to measure objectively the severity of the cortical opacity. These metrics could be implemented in an algorithm to detect and grade lens opacities automatically and objectively.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative analysis of the nuclear lens opalescence by the Lens Opacities Classification System III with nuclear density values provided by Oculus Pentacam: a cross-section study using Pentacam Nucleus Staging software.

PURPOSE To compare the clinical classification of cataract using the Lens Opacities Classification System (LOCS) III with the mean values of lens density provided by the Pentacam Scheimpflug System in nuclear cataracts. METHODS One hundred and one eyes from 101 patients with age-related nuclear cataract were submitted to clinical examination for lens grading score using LOCS III. According to...

متن کامل

Grading nuclear, cortical and posterior subcapsular cataracts using an objective scatter index measured with a double-pass system.

PURPOSE To evaluate objectively intraocular scattering in eyes with nuclear, cortical and posterior subcapsular cataracts by means of an objective scatter index (OSI) obtained from double-pass images. To compare the results with those obtained using clinical conventional procedures. METHODS In this prospective, observational, cross-sectional, non-consecutive case series study, 188 eyes with c...

متن کامل

Clinical importance of the lens opacities classification system III (LOCS III) in phacoemulsification.

The aim of this study was to compare the correlation of features of cataracts graded by the Lens Opacities Classification System, version III (LOCS III) with recorded operative characteristics during the phacoemulsification. The retrospective study included 245 cases operated on by a single surgeon from October 2003 to March 2004. The cataract was graded at the biomicroscope using the 4 grading...

متن کامل

Study of nuclear cataract progression using the National Eye Institute Scheimpflug system.

AIMS A study was conducted to determine the capability of the recently developed National Eye Institute (NEI) Scheimpflug cataract imaging system in detecting changes in the nuclear region of the lens over a 1 year period. METHODS Twenty five eyes with pure nuclear cataracts with mean nuclear densities < or = 0.30 optical density units (ODU) as well as 30 normal control eyes were each examine...

متن کامل

Quantitative Analysis of Lens Nuclear Density Using Optical Coherence Tomography (OCT) with a Liquid Optics Interface: Correlation between OCT Images and LOCS III Grading

Purpose. To quantify whole lens and nuclear lens densities using anterior-segment optical coherence tomography (OCT) with a liquid optics interface and evaluate their correlation with Lens Opacities Classification System III (LOCS III) lens grading and corrected distance visual acuity (BCVA). Methods. OCT images of the whole lens and lens nucleus of eyes with age-related nuclear cataract were a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016