Determination of Diffusion Characteristics Using Two- and Four-Point Probe Measurements
نویسندگان
چکیده
By the use of twoand four-point probe measurements, much can be learned about the characteristics of a doped silicon wafer. The two-point probe system (spreading resistance probe) will provide resistivity vs depth profiles while the four-point probe system will indicate the uniformity of the diffusion over the surface of the wafer. Both systems have the same equation as their basis. The development of each system from this equation is discussed. Applications and the strengths and weaknesses of each system are discussed.
منابع مشابه
Bayesian Sample Size Determination for Joint Modeling of Longitudinal Measurements and Survival Data
A longitudinal study refers to collection of a response variable and possibly some explanatory variables at multiple follow-up times. In many clinical studies with longitudinal measurements, the response variable, for each patient is collected as long as an event of interest, which considered as clinical end point, occurs. Joint modeling of continuous longitudinal measurements and survival time...
متن کاملA Novel Technique for Determination of the Onset of Alkane Induced Asphaltene Precipitation Using Accurate Density Measurements
Onset of asphaltene precipitation is the key parameter in dealing with asphaltene problems because it is the starting point of the asphaltene separation from the solution. In this study, a new technique is provided based on the experimental observations for the determination of the onset of asphaltene precipitation using accurate density measurements of the crude oils upon titration with precip...
متن کاملProbe diffusion in phase-separated bicontinuous biopolymer gels.
Probe diffusion was determined in phase separated bicontinuous gels prepared by acid-induced gelation of the whey protein isolate-gellan gum system. The topological characterization of the phase-separated gel systems is achieved by confocal microscopy and the diffusion measurements are performed using pulsed field gradient (PFG) NMR and fluorescence recovery after photo-bleaching (FRAP). These ...
متن کاملبررسی عملکرد پروبهای UHF در آشکارسازی تخلیه جزئی در ترانسفورماتورهای فشار قوی
Recently, UHF partial discharge (PD) detection on power transformers attracts lots of attentions. For the transformers already installed in power network, the UHF signals can be captured only by UHF probes installed through oil drain valve. Although UHF probes are commercially produced, there are a lot of missing information on characteristics and features of these probes for PD detection. In t...
متن کاملDetermination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods
High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002