Intracranial Hematoma Detection by Near Infrared Spectroscopy in a Helicopter Emergency Medical Service: Practical Experience
نویسندگان
چکیده
In (helicopter) emergency medical services, (H)EMS, the prehospital detection of intracranial hematomas should improve patient care and the triage to specialized neurosurgical hospitals. Recently, noninvasive detection of intracranial hematomas became possible by applying transcranial near infrared spectroscopy (NIRS). Herein, second-generation devices are currently available, for example, the Infrascanner 2000 (Infrascan), that appear suited also for prehospital (H)EMS applications. Since (H)EMS operations are time-critical, we studied the Infrascanner 2000 as a "first-time-right" monitor in healthy volunteers (n = 17, hospital employees, no neurologic history). Further, we studied the implementation of the Infrascanner 2000 in a European HEMS organization (Lifeliner 1, Amsterdam, The Netherlands). The principal results of our study were as follows: The screening for intracranial hematomas in healthy volunteers with first-time-right intention resulted in a marked rate of virtual hematomas (false positive results, i.e., 12/17), rendering more time consuming repeat measurements advisable. The results of the implementation of the Infrascanner in HEMS suggest that NIRS-based intracranial hematoma detection is feasible in the HEMS setting. However, some drawbacks exist and their possible solutions are discussed. Future studies will have to demonstrate how NIRS-based intracranial hematoma detection will improve prehospital decision making in (H)EMS and ultimately patient outcome.
منابع مشابه
Clinical application of near-infrared spectroscopy in patients with traumatic brain injury: a review of the progress of the field.
Near-infrared spectroscopy (NIRS) is a technique by which the interaction between light in the near-infrared spectrum and matter can be quantitatively measured to provide information about the particular chromophore. Study into the clinical application of NIRS for traumatic brain injury (TBI) began in the 1990s with early reports of the ability to detect intracranial hematomas using NIRS. We hi...
متن کاملNear-infrared laser spectroscopy as a screening tool for detecting hematoma in patients with head trauma.
INTRODUCTION Among imaging techniques, computed tomography (CT) is a reliable method for detecting intracranial hematomas in patients with head trauma, but it is not generally available in special circumstances like prehospital situations and harsh conditions such as those following an earthquake. OBJECTIVE The objective of this study is to determine if near-infrared spectroscopy (NIRS) is us...
متن کاملInvestigation of the Correlation between Scalp Hematoma and Cranial Fractures and Intracranial Lesions in Children Presenting with Minor Head Trauma
Introduction: Minor head trauma is one of the common causes of pediatric reference to emergency ward. This study investigated the correlation between scalp hematoma,cranial fractures and intracranial lesions in children presenting with minor head traumata. Methods: This was a descriptive cross-sectional study. The data gathering were done in 2016-17. All children under 18 years of age (933 ind...
متن کاملCorrelation of intraoperative renal near infrared spectroscopy with the development of acute kidney injury in adult patients undergoing cardiac surgery using cardiopulmonary bypass
Introduction: The present study aimed to correlate renal oximetry near-infrared spectroscopy (NIRS) values with conventional non-invasive biomarkers for the early detection of acute kidney injury (AKI) in adult patients undergoing cardiac surgery using cardiopulmonary bypass (CPB). Accordingly, renal NIRS can be employed as a trending device for the prevention of AKI developmen...
متن کاملNovel Application of Near-infrared Spectroscopy and Chemometrics Approach for Detection of Lime Juice Adulteration
The aim of this study is to investigate the novel application of a handheld near infra-red spectrophotometer coupled with classification methodologies as a screening approach in detection of adulterated lime juices. For this purpose, a miniaturized near infra-red spectrophotometer (Tellspec®) in the spectral range of 900–1700 nm was used. Three diffuse reflectance spectra of 31 pure...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2017 شماره
صفحات -
تاریخ انتشار 2017