A luminous efficiency function , V * ( 1 ) , for daylight adaptation

نویسندگان

  • Lindsay T. Sharpe
  • Andrew Stockman
  • Wolfgang Jagla
  • Herbert Jägle
چکیده

We propose a new luminosity function, V ð1Þ, that improves upon the original CIE 1924 Vð1Þ function and its modification by D. B. Judd (1951) and J. J. Vos (1978), while being consistent with a linear combination of the A. Stockman & L. T. Sharpe (2000) long-wavelength-sensitive (L) and middle-wavelength-sensitive (M) cone fundamentals. It is based on experimentally determined 25 Hz, 2diameter, heterochromatic (minimum) flicker photometric data obtained from 40 observers (35 males, 5 females) of known genotype, 22 with the serine variant L(ser180), 16 with the alanine L(ala180) variant, and 2 with both variants of the L-cone photopigment. The matches, from 425 to 675 nm in 5-nm steps, were made on a 3 log troland xenon white (correlated color temperature of 5586 K but tritanopically metameric with CIE D65 standard daylight for the Stockman and Sharpe Land M-cone fundamentals in quantal units) adapting field of 16angular subtense, relative to a 560-nm standard. Both the reference standard and test lights were kept near flicker threshold so that, in the region of the targets, the total retinal illuminance averaged 3.19 log trolands. The advantages of the new function are as follows: it forms a consistent set with the new proposed CIE cone fundamentals (which are the Stockman & Sharpe 2000 cone fundamentals); it is based solely on flicker photometry, which is the standard method for defining luminance; it corresponds to a central 2viewing field, for which the basic laws of brightness matching are valid for flicker photometry; its composition of the serine/alanine L-cone pigment polymorphism (58:42) closely matches the reported incidence in the normal population (56:44; Stockman & Sharpe, 1999); and it specifies luminance for a reproducible, standard daylight condition. V ð1Þ is defined as 1:55Lð1Þ þMð1Þ, where Lð1Þ and Mð1Þ are the Stockman & Sharpe L& M-cone (quantal) fundamentals. It is extrapolated to wavelengths shorter than 425 nm and longer than 675 nm using the Stockman & Sharpe cone fundamentals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Luminous efficiency and the measurement of daytime displays, signals, and visors.

PURPOSE Measurements concerning the usability or safety of optical equipment are based on assumptions regarding luminous efficiency. The current luminous efficiency functions are derived from human sensitivity experiments taken at low light levels compared with the outdoor daytime environment. The amount of error induced by extrapolating from low light level data to high light level application...

متن کامل

Analysis of optimum window-to-wall ratio in Horizontal expanded and vertical expanded windows, Tehran, Iran

Good daylighting design in buildings not only provides a comfortable luminous environment, but also delivers energy savings and comfortable and healthy environments for building occupants. The importance of using daylight in educational buildings is because of the synchrony of operating hours of the school and daylight plenitude the sky. Daylight improves environmental quality and saves energy ...

متن کامل

The effects of daylighting and human behavior on luminous comfort in residential buildings: A questionnaire survey

A questionnaire survey was conducted to investigate the effects of daylighting and human behavior patterns on subjective luminous comfort in Hong Kong housing units. The participants were recruited via mail, and included residents of both public and private housing units. 340 questionnaires were returned and analyzed by using SPSS 19.0. In analyzing the response statistics, the Cronbach's alpha...

متن کامل

Luminous-efficiency functions for point sources.

Luminous-efficiency functions for small fields were measured with flicker photometry and heterochromatic brightness-matching methods for the same two subjects. For the larger stimuli (22.9 and 11.5'), the luminous-efficiency functions differed between the two methods. Those obtained by flicker photometry showed a simple narrow shape, whereas those obtained by heterochromatic brightness matching...

متن کامل

CIE Colorimetry and Colour Displays

CIE colorimetry was standardised 65 years ago to describe colorimetric properties of signal lights. The first real application of CIE colorimetry occurred, however, in the textile and coating industries to describe colour matches between sample and reference. Thus also the experiments conducted to achieve a uniform colour scale diagram were performed by using material samples usually illuminate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005