Quantification of breast density with spectral mammography

نویسندگان

  • Travis Johnson
  • Huanjun Ding
  • Lee-Jane W Lu
  • Thomas K Nishino
  • Pavlo Baturin
  • Yahya Alivov
  • Katharina Holland
  • Albert Gubern-Mérida
  • Ritse M Mann
  • Sabee Molloi
چکیده

A simple and accurate measurement of breast density is crucial for the understanding of its impact in breast cancer risk models. The feasibility to quantify volumetric breast density with a photon-counting spectral mammography system has been investigated using both computer simulations and physical phantom studies. A computer simulation model involved polyenergetic spectra from a tungsten anode x-ray tube and a Si-based photoncounting detector has been evaluated for breast density quantification. The figure-of-merit (FOM), which was defined as the signal-to-noise ratio of the dual energy image with respect to the square root of mean glandular dose, was chosen to optimize the imaging protocols, in terms of tube voltage and splitting energy. A scanning multi-slit photon-counting spectral mammography system has been employed in the experimental study to quantitatively measure breast density using dual energy decomposition with glandular and adipose equivalent phantoms of uniform thickness. Four different phantom studies were designed to evaluate the accuracy of the technique, each of which addressed one specific variable in the phantom configurations, including thickness, density, area and shape. In addition to the standard calibration fitting function used for dual energy decomposition, a modified fitting function has been proposed, which brought the tube voltages used in the imaging tasks as the third variable in dual energy decomposition. For an average sized 4.5 cm thick breast, the FOM was maximized with a tube voltage of 46 kVp and a splitting energy of 24 keV. To be consistent with the tube voltage used in current clinical screening exam (∼32 kVp), the optimal splitting energy was proposed to be 22 keV, which offered a FOM greater than 90% of the optimal value. In the experimental investigation, the root-mean-square (RMS) error in breast density quantification for all four phantom studies was estimated to be approximately 1.54% using standard calibration function. The results from the modified fitting function, 1 Author to whom any correspondence should be addressed. 0031-9155/12/154719+20$33.00 © 2012 Institute of Physics and Engineering in Medicine Printed in the UK & the USA 4719 4720 H Ding and S Molloi which integrated the tube voltage as a variable in the calibration, indicated a RMS error of approximately 1.35% for all four studies. The results of the current study suggest that photon-counting spectral mammography systems may potentially be implemented for an accurate quantification of volumetric breast density, with an RMS error of less than 2%, using the proposed dual energy imaging technique. (Some figures may appear in colour only in the online journal)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Factors Affecting the Mammographic Density of Breast Tissue in Patients Referred to the Breast Cancer Research Center, Iran

Introduction: Of the factors leading to false negative results in mammography is breast tissue density, and by increasing the density of breast tissue in mammography, the mammography sensitivity decreases. On the other hand, increasing the breast tissue density leads to increased risk of breast cancer. Various factors such as inheritance, genetics, hormonal and reproductive factors, and nutriti...

متن کامل

Investigating the Factors Affecting the Mammographic Density of Breast Tissue in Patients Referred to the Breast Cancer Research Center, Iran

Introduction: Of the factors leading to false negative results in mammography is breast tissue density, and by increasing the density of breast tissue in mammography, the mammography sensitivity decreases. On the other hand, increasing the breast tissue density leads to increased risk of breast cancer. Various factors such as inheritance, genetics, hormonal and reproductive factors, and nutriti...

متن کامل

تاثیر درمان جایگزینی با هورمون (HRT) بر حساسیت ماموگرافی غربالگری در خانم های یائسه

Background and purpose:The risk of developing breast cancer during the liftime of females is 12.5% (about 1 in 8). Ïn addition hormone replacement therapy is part of the preventive measure in women at their menopausal period. Studies have revealed that screening mammography changes with age, mammographyic density and family history of breast cancer. This study was designed to evaluate the bre...

متن کامل

بررسی نقش سونوگرافی تکمیلی در تشخیص سرطان پستان

Introduction & Objective: The breast cancer is the most common malignancy in women and in recent years it is seen in younger ages. Because of dense breast tissue in these ages, the mammography sensitivity for breast cancer detection is reduced, so high quality ultrasonography (US) as a combined screening method is effective. The aim of this study is the evaluation of the mammographic finding ...

متن کامل

مقایسه تغییرات ماموگرافیک در دو نوع رژیم رایج هورمون درمانی جایگزین بعد از یائسگی

  Background & Objective : Nowadays breast cancer is one of the most causes of female mortality. Mammography is a valuable method for early detection of breast cancer. Mammographic sensitivity depends on some factors such as age, breast tissue density, menopausal status, systemic disease, familial history of breast cancer and others. This study was designed to compare the effects of two regimen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012