Correlation of Dga, Uhf Pd Measurement and Vibration Data for Power Transformer Monitoring

نویسندگان

  • A. Müller
  • M. Beltle
  • S. Coenen
  • S. Tenbohlen
چکیده

Reliability of electrical energy networks depends on quality and availability of electrical equipment like power transformers. Local failures inside their insulation may lead to catastrophic breakdowns. To prevent destroying events power transformers are e.g. tested on partial discharge (PD) activity. As testing is just snapshot information about transformers condition, permanent online monitoring is more frequently used to gain operational experiences. The paper presents a monitoring case study of an aged generator step-up transformer with PD activity. Different measurement methods considering different transformer parameters are introduced. Correlation of data for information gain regarding the insulation condition assessment is discussed with the help of a recorded incident with high PD level and followed rise in gas concentration. A Hydran sensor is used to measure the actual level and the trend of dissolved gasses. The presented monitoring system uses the electromagnetic PD measurement method, also known as UHFmethod. PD emitted electromagnetic waves are monitored with an oil valve sensor inside the transformer tank. Furthermore vibration monitoring is included, representing a new approach for transformer surveillance. In addition common measurements were performed for evaluation and correlation purpose, including load current, voltage, top-oil and ambient temperature of the transformer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Partial Discharge Monitoring of Power Transformers by UHF Sensors

The reliability of electrical energy networks depends on both, the quality and the reliability of its electrical equipment, e.g. power transformers. Local failures inside their insulation can lead to breakdowns and hence to high outage and penalty costs. Usually, power transformers are tested on partial discharge (PD) activity before commissioning. UHF PD monitoring can be used to prevent these...

متن کامل

TE-Monitoring von Leistungstransformatoren mittels UHF Sensoren

The reliability of electrical energy networks depends on both the quality and the reliability of its electrical equipment, e.g. power transformers. Local failures inside their insulation can lead to breakdowns and hence to high outage and penalty costs. Usually, power transformers are tested on partial discharge (PD) activity before commissioning. UHF PD monitoring can be used to prevent these ...

متن کامل

بررسی عملکرد پروب‌های UHF در آشکارسازی تخلیه جزئی در ترانسفورماتورهای فشار قوی

Recently, UHF partial discharge (PD) detection on power transformers attracts lots of attentions. For the transformers already installed in power network, the UHF signals can be captured only by UHF probes installed through oil drain valve. Although UHF probes are commercially produced, there are a lot of missing information on characteristics and features of these probes for PD detection. In t...

متن کامل

Comparison between Electrical and UHF PD Measurement concerning Calibration and Sensitivity for Power Transformers

The application of regular condition checks and continuous monitoring of power transformers gains in importance. Nowadays, these methods are frequently used to detect damages in the insulation system at early stage and thus to avoid outages. In addition to the electrical partial discharge (PD) measurement according IEC 60270 [1], the electromagnetic measurement method starts to become common pr...

متن کامل

On-site Portable Partial Discharge Detection Applied to Power Cables Using HFCT and UHF methods

Partial discharge (PD) events happen inside the power cables and cable terminations with the insulation degradation. The PD detection can effectively supply the information of cable status. According to the electrical and electromagnetic emission of PD activities, high-frequency transformer (HFCT) and ultrahigh-frequency (UHF) methods are employed to detect the PD signals. Besides, a portable P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011