A non-electrostatic spacer for aerosol delivery.

نویسندگان

  • H Bisgaard
  • J Anhøj
  • B Klug
  • E Berg
چکیده

A pear shaped non-electrostatic spacer, composed of steel with a volume of 250 ml and equipped with a facemask containing integrated inlet and outlet valves for inspiration and expiration, was compared with three plastic spacers. The plastic spacers were primed with repeated puffs from a budesonide pressurised metered dose inhaler (p-MDI) to minimise the electrostatic charge on the plastic. The procedure prolonged the half life (t1/2) of the aerosol in the Nebuhaler from nine to 32 seconds. A normal cleaning procedure reduced the aerosol t1/2 back to baseline. The t1/2 of the aerosol in the metal spacer was 27 seconds and independent of the use of p-MDI. In vitro the maximum dose of budesonide from a p-MDI, expressed as a percentage of the nominal dose, was 56% from the non-electrostatic spacer, 61% from the Nebuhaler, 45% from the Babyhaler, and 30% from the AeroChamber. In 124 children, age 6 months to 6 years, suspected to have asthma the non-electrostatic spacer delivered a mean total dose of budesonide aerosol of 39% of the nominal dose, which was significantly higher than the Babyhaler (28%), the Nebuhaler (21%), and the AeroChamber (19%). These differences were most pronounced in children younger than 4 years. The improved dose delivery from the small volume non-electrostatic spacer is probably related to the non-electrostatic spacer material and the valves which assured unidirectional airflow from the spacer without adding any dead space in the inspiratory channel. The non-electro-static spacer should improve the cost effectiveness of aerosol treatment and, as the counteracting effects of proming and recharging of the plastic from cleaning are avoided, should deliver a more reliable dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aerosol delivery from spacers in wheezy infants: a daily life study.

The aims of this study were to assess and compare dose delivery and dose variability of pressurized metered dose inhalers (pMDI)/spacers in wheezy infants in daily life and to investigate factors influencing aerosol delivery. In an open randomized crossover study in 25 wheezy infants aged 5-26 months, a metal spacer (Nebuchamber), a detergent coated (DC) and a non-detergent coated (nonDC) plast...

متن کامل

Factors affecting the efficiency of aerosol therapy with pressurised metered-dose inhalers through plastic spacers.

AIM The main objective of this study was to compare the in vitro delivery of salbutamol from a chlorofluorocarbon(CFC)-propelled pressurised metered-dose inhaler (pMDI) versus a newly developed hydrofluoroalkane(HFA)-propelled pMDI through various spacers. In addition, we aimed to study the effect on bronchodilator response when using an optimal pMDI/spacer combination for aerosol delivery comp...

متن کامل

The effects of static charge in spacer devices on glucocorticosteroid aerosol deposition in asthmatic patients.

Electrostatic charge in plastic spacer devices has been shown in vitro to reduce delivery of asthma medications intended for inhalation, but the effect of static charge on in vivo drug deposition is unknown. A six-way randomized crossover study was conducted in 10 mild asthmatic patients. Two plastic spacers (Nebuhaler and Volumatic) and one metal spacer (Nebuchamber) were tested. The spacers w...

متن کامل

Randomised controlled study of clinical efficacy of spacer therapy in asthma with regard to electrostatic charge.

BACKGROUND Inhalation therapy using a pressured metered dose inhaler (pMDI) and a spacer is frequently used in the treatment of airway disease in children. Several laboratory studies found a clear negative influence of electrostatic charge (ESC) on plastic spacers on the delivery of aerosol. AIMS To investigate whether ESC on plastic spacers could diminish bronchodilating responses to salbuta...

متن کامل

Special problems in aerosol delivery: artificial airways.

Several factors interact in influencing aerosol deposition during mechanical ventilation. Among these factors, the artificial airway is a significant barrier for aerosol deposition. Earlier studies overemphasized the impediments created by the artificial airway to aerosol delivery, because the aerosol generator was placed adjacent to the endotracheal tube or was connected to it. When the aeroso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood

دوره 73 3  شماره 

صفحات  -

تاریخ انتشار 1995