A comparison of oesophageal and central venous pressures in the measurement of transpulmonary pressure change.
نویسندگان
چکیده
Oesophageal (oes) and central venous pressure (CVP) were compared as indices of transpulmonary pressure change (deltap). The mean increase of deltaPoes over deltapCVP was 2.8 cm H2O. The size and variability of the increase were similar to the expected difference between oesophageal and pleural pressure fluctuations occurring in the supine patient. Central venous pressure may be more accurate and reliable than oesophageal pressure for estimations of transpulmonary pressure change in the supine position.
منابع مشابه
Determination of Central Venous Pressure from Intraocular Pressure
Background: In many clinical situations, knowledge of central venous pressure (CVP) is important. Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery. Those with carotid artery or jugular venous diseases as we...
متن کاملبررسی تأثیر استفاده از چک لیست ثبت اقدامات بر عملکرد پرستاران بخش مراقبت های ویژه در اندازهگیری فشار ورید مرکزی
Background & Aim: The central venous pressure measurement is a common and important care provided by nurses in intensive units. The measurement should be according to the pre-defined standards. The purpose of this study was to evaluate the effect of using a checklist in measuring central venous pressure by nurses . Methods & Materials: This was a nonequivalent group design on 70 nurses w...
متن کاملCorrelation of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index with Central Venous Pressure in Diagnosis and Management of Neonatal Shock
Background: Neonatal intensive care unit (NICU)Conventionally, Central Venous Pressure (CVP) monitoring has beenused by intensivists to measure intravascular volume. However, it is an invasive procedure resulting in many complications. Non-invasive ultrasonographic measurement of inferior vena cava collapsibility index (IVC-CI) is a promising alternative. Therefore, this study wasconducte...
متن کاملComparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement
Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...
متن کاملاثر تزریق مداوم (اینفیوژن) دوزپائین کتامین برتغییرات همودینامیک در جراحی پیوند عروق کرونر
Background & objectives: Cardiopulmonary bypass often causes a stress hormonal response with subsequent changes in hemodynamic and organ perfusion. Human studies involving cardiopulmonary bypass have shown that very low doses of ketamine can attenuate inflammatory and stress markers, without adverse effects. The aim of this study was to investigate whether low dose infusion of ketamine have hem...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 48 5 شماره
صفحات -
تاریخ انتشار 1976