Fifth-generation digital immunoassay for prostate-specific antigen by single molecule array technology.

نویسندگان

  • David H Wilson
  • David W Hanlon
  • Gail K Provuncher
  • Lei Chang
  • Linan Song
  • Purvish P Patel
  • Evan P Ferrell
  • Herbert Lepor
  • Alan W Partin
  • Dan W Chan
  • Lori J Sokoll
  • Carol D Cheli
  • Robert P Thiel
  • David R Fournier
  • David C Duffy
چکیده

BACKGROUND Measurement of prostate-specific antigen (PSA) in prostate cancer patients following radical prostatectomy (RP) has been hindered by the limit of quantification of available assays. Because radical prostatectomy removes the tissue responsible for PSA production, postsurgical PSA is typically undetectable with current assay methods. Evidence suggests, however, that more sensitive determination of PSA status following RP could improve assessment of patient prognosis and response to treatment and better target secondary therapy for those who may benefit most. We developed an investigational digital immunoassay with a limit of quantification 2 logs lower than current ultrasensitive third-generation PSA assays. METHODS We developed reagents for a bead-based ELISA for use with high-density arrays of femtoliter-volume wells. Anti-PSA capture beads with immunocomplexes and associated enzyme labels were singulated within the wells of the arrays and interrogated for the presence of enzymatic product. We characterized analytical performance, compared its accuracy with a commercially available test, and analyzed longitudinal serum samples from a pilot study of 33 RP patients. RESULTS The assay exhibited a functional sensitivity (20% interassay CV) <0.05 pg/mL, total imprecision <10% from 1 to 50 pg/mL, and excellent agreement with the comparator method. All RP samples were well within the assay measurement capability. PSA concentrations following surgery were found to be predictive of prostate cancer recurrence risk over 5 years. CONCLUSIONS The robust 2-log improvement in limit of quantification relative to current ultrasensitive assays and the validated analytical performance of the assay allow for accurate assessment of PSA status after RP.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Age Specific Reference Levels of Serum Prostate-Specific Antigen, Prostate Volume and Prostate Specific Antigen Density in Healthy Iranian Men

Background: It is relevant to highlight that there is not a precise and perfect report on either 95 percentile value (upper limit of normal range) or on appropriate reference intervals for serum PSA in Iranian population. Objective: To determine age-specific reference ranges for serum prostate-specific antigen (PSA) concentration and PSA density (PSAD) and prostate volumes in a population of he...

متن کامل

A Simplified and Reproducible Two-Step Method for the Purification of Prostate-Specific Antigen

Prostate-specific antigen (PSA) was purified to homogeneity from human seminal plasma by ion-exchange chromatography on a CM-Sephadex C-50 and by gel filtration on a Sephacryl S-200 column. A single 33-kDa protein band appeared in SDS-PAGE. High pressure liquid chromatography (HPLC) of the purified protein produced a single peak, while isoelectric focusing demonstrated the presence of five diff...

متن کامل

Large-scale femtoliter droplet array for digital counting of single biomolecules.

We present a novel device employing one million femtoliter droplets immobilized on a substrate for the quantitative detection of extremely low concentrations of biomolecules in a sample. Surface-modified polystyrene beads carrying either zero or a single biomolecule-reporter enzyme complex are efficiently isolated into femtoliter droplets formed on hydrophilic-in-hydrophobic surfaces. Using a c...

متن کامل

Designing a Radioimmunometric Assay Kit for Prostate-Specific Antigen Measurement Using Polystyrene Tubes Coated By Immunochemical Method

ABSTRACT &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Background and Objective: Prostate specific antigen (PSA) is considered as one of the most reliable biomarkers of cancer and other known prostate diseases. In the present study, solid phase sandwich immunoradiometric assay was used to measure the amount of PSA. In this type of measurement, a pair of anti-PSA antibodies on the solid phase and la...

متن کامل

What is the most appropriate test in detecting prostate cancer in patients with intermediate prostate specific antigen levels?

  Abstract   Background: Regarding the variety of tests present for detecting and also screening   prostate cancer and also bearing in mind the advantages and disadvantages of   these tests we decided to re-evaluate these tests (total prostate specific antigen and all   of its modifications) in detecting prostate cancer in men with intermediate serum   PSAlevels.   Methods: Following a cross se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 57 12  شماره 

صفحات  -

تاریخ انتشار 2011