Coracohumeral Distances and Correlation to Arm Rotation: An In Vivo 3-Dimensional Biplane Fluoroscopy Study.

نویسندگان

  • John P Brunkhorst
  • J Erik Giphart
  • Robert F LaPrade
  • Peter J Millett
چکیده

BACKGROUND Reduced coracohumeral distances have been reported to be associated with anterior shoulder disorders such as subscapularis tears, biceps tendon injuries, and leading edge supraspinatus tears. PURPOSE To determine the variability in coracohumeral distance as a function of arm rotation in healthy male subjects. The null hypothesis was that no differences in coracohumeral distance would exist with respect to arm rotation. STUDY DESIGN Descriptive laboratory study. METHODS A total of 9 male participants who had full range of motion, strength, and no prior surgery or symptoms in their tested shoulders were enrolled in this institutional review board-approved study. Computed tomography scans of the shoulder were obtained for each subject. A dynamic biplane fluoroscopy system recorded internal and external shoulder rotation with the arm held in the neutral position. Three-dimensional reconstructions of each motion were generated, and the coracohumeral distance and coracoid index (lateral extension of the coracoid) were measured. RESULTS The mean coracohumeral distance in neutral rotation was 12.7 ± 2.1 mm. A significantly shorter minimum coracohumeral distance of 10.6 ± 1.8 mm was achieved (P = .001) at a mean glenohumeral joint internal rotation angle of 36.6° ± 19.2°. This corresponded to a reduction in coracohumeral distance of 16.4% (range, 6.6%-29.8%). The mean coracoid index was 14.2 ± 6.8 mm. A moderate correlation (R = -0.75) existed between the coracohumeral distance and coracoid index. CONCLUSION Coracohumeral distance was reduced during internal rotation. Decreased coracohumeral distance was correlated with larger coracoid indices. CLINICAL RELEVANCE This study provides a reference value for coracohumeral distance in the healthy male population. Knowledge of how coracohumeral distance varies over the range of arm internal-external rotation may improve the clinical diagnosis and treatment plan for patients with anterior shoulder pathology, specifically subcoracoid impingement. Imaging of the coracohumeral distance during internal rotation with the hand at approximately midline should be considered to assess patients with anterior shoulder pain.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of arm elevation on the 3-dimensional acromiohumeral distance: a biplane fluoroscopy study with normative data.

HYPOTHESIS AND BACKGROUND Narrowing of the subacromial space has been implicated in several shoulder pathologies. However, the location of the minimum distance points during clinical testing has not been defined. We sought to measure the in vivo minimum distance and location of the minimum distance points on the acromion and proximal humerus during arm elevation. METHODS Eight healthy male su...

متن کامل

Triangle Tilt Surgery: Effect on Coracohumeral Distance and External Rotation of the Glenohumeral Joint

OBJECTIVE Shoulder muscle imbalances and bone deformities that develop secondary to obstetric brachial plexus injury have been extensively studied. Less emphasis has focused on coracohumeral distance, a small value potentially being linked to impaired shoulder external rotation. The purpose of this study is to analyze coracohumeral distances and shoulder external rotation in obstetric brachial ...

متن کامل

Restricted scapular mobility during arm abduction: implications for impingement syndrome.

Scapular mobility plays a central role in normal shoulder function, and alterations in scapular mobility have been suggested as a factor in impingement syndrome. We therefore measured the effect of restricted scapular mobility during arm abduction on acromiohumeral and coracohumeral distances. For the control measurements, healthy volunteers (n = 10, all male, age range 25-35 years) underwent m...

متن کامل

Three-Dimensional Morphometric Analysis of the Coracohumeral Distance Using Magnetic Resonance Imaging

There have been no studies investigating three-dimensional (3D) alteration of the coracohumeral distance (CHD) associated with shoulder motion. The aim of this study was to investigate the change of 3D-CHD with the arm in flexion/internal rotation and horizontal adduction. Six intact shoulders of four healthy volunteers were obtained for this study. MRI was taken in four arm positions: with the...

متن کامل

Three-Dimensional Digital Sonomicrometry: Comparison with Biplane Radiography

This paper describes a three-dimensional (3D) digital sonomicrometry approach for locating and tracking 3D objects. A commercial digital sonomicrometry system was employed to measure scalar distances between omnidirectional sonomicrometers. 3D coordinates were then derived using the statistical technique of multidimensional scaling (MDS). 3D digital sonomicrometry was directly compared with bip...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopaedic journal of sports medicine

دوره 1 2  شماره 

صفحات  -

تاریخ انتشار 2013