Pointwise assessment of three-dimensional computer reconstruction of mitral leaflet surfaces from rotationally scanned echocardiograms in vitro.
نویسندگان
چکیده
Three-dimensional transesophageal echocardiography offers promise for improved understanding of mitral leaflet pathology, but it has not been validated quantitatively, nor has the minimum number of imaging planes for satisfactory reconstruction been determined with a rotational scanning geometry. This study assessed its accuracy in vitro by comparing, on a 1 x 1-mm grid, the surfaces of mitral leaflets derived from 5-degree rotational ultrasonic scans with those derived from laser scans of casts of the atrial side of the leaflets. Overall, the ultrasonically derived surface had a mean absolute deviation of 0.65 +/- 0.12 mm from the laser-derived surface. Using only alternate imaging planes (10-degree increments) made no significant difference in the overall distribution of deviations (P =.56), although the distributions on some individual specimens differed markedly. We conclude that 5-degree rotational scanning in vitro can reconstruct the mitral valve leaflets with sufficient accuracy and detail to render clinically important features.
منابع مشابه
Three-dimensional echocardiographic reconstruction of the mitral valve, with implications for the diagnosis of mitral valve prolapse.
Mitral valve prolapse has been diagnosed by two-dimensional echocardiographic criteria with surprising frequency in the general population, even when preselected normal subjects are examined. In most of these individuals, however, prolapse appears in the apical four-chamber view and is absent in roughly orthogonal long-axis views. Previous studies of in vitro models with nonplanar rings have sh...
متن کاملMitral Valve Prolapse
Mitral valve prolapse has been diagnosed by two-dimensional echocardiographic criteria with surprising frequency in the general population, even when preselected normal subjects are examined. In most of these individuals, however, prolapse appears in the apical four-chamber view and is absent in roughly orthogonal long-axis views. Previous studies of in vitro models with nonplanar rings have sh...
متن کاملPreoperative echocardiographic diagnosis of anterior mitral valve leaflet fenestration associated with infective endocarditis.
Previously unreported echocardiographic findings are described of two cases with anterior mitral valve leaflet fenestration associated with infective endocarditis. M-mode echocardiograms demonstrated a periodic interruption in the echo tracing of the mitral valve ring area. Long axis real time two dimensional echocardiograms showed an echo defect in the body portion of the anterior mitral valve...
متن کاملThree-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography
The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...
متن کاملUse of digitised left ventricular echocardiograms in assessment of mitral stenosis.
In order to establish a new echocardiographic index of the severity of mitral stenosis, left ventricular echocardiograms were digitised using manual tracing and a computer. The instantaneous left ventricular dimension was measured in 15 patients with mitral stenosis. The peak rate of change of left ventricular dimension (peak dD/dt) and the normalised peak rate (peak dD/dt/D) during early diast...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
دوره 17 3 شماره
صفحات -
تاریخ انتشار 2004