Intravascular ultrasound measurement of the aortic lumen.
نویسندگان
چکیده
Intravascular ultrasound (IVUS) has been successfully used to guide the implantation of stents in the thoracic aorta. However, its accuracy in measuring the diameter of the aortic lumen has not been clearly established. Thirteen patients with thoracic aortic disease underwent IVUS, and lumen diameter measurements were compared with those obtained by CT or magnetic resonance imaging. A total of 31 comparable measurements were obtained. The correlation was good (r=0.98; P< .001), with IVUS tending to give a larger minimum diameter than CT (systematic error, 0.59+/-1.8 mm; P=.077). Given that the aorta is often not circular, the diameter obtained by IVUS was also compared to the mean diameter obtained by CT, and it was found that these two measurements were more closely related (P=.425), except in aortic segments with significant eccentricity (i.e., >10%). In conclusion, IVUS was a reliable tool for measuring the diameter of the aorta, particularly in concentric segments where stents are normally placed. Consequently, IVUS could supplement conventional imaging techniques.
منابع مشابه
Novel intravascular ultrasound-guided method to create transintimal arterial communications: initial experience in peripheral occlusive disease and aortic dissection.
PURPOSE To report our experience using a commercially available catheter-based system equipped with an intravascular ultrasound (IVUS) transducer to achieve controlled true lumen re-entry in patients undergoing subintimal angioplasty for chronic total occlusions (CTO) or aortic dissections. METHODS During an 8-month period, 10 patients (6 men; mean age 73.4 years) with lower extremity (LE) is...
متن کاملIntraluminal ultrasound imaging through a balloon dilation catheter in an animal model of coarctation of the aorta.
BACKGROUND Controversy still exists over the optimal balloon size, extent of vascular disruption, and long-term results of balloon dilation therapy for coarctation of the aorta. Intravascular ultrasound imaging has been used in patients with coronary artery disease to provide further insight into the anatomy of atherosclerotic lesions and the results of angioplasty and atherectomy. Initial obse...
متن کاملاندازه گیری قطر قدامی – خلفی ورید اجوف تحتانی توسط سونوگرافی به عنوان یک روش غیر تهاجمی در تخمین میزان فشار ورید مرکزی در بیماران بستری در بخش مراقبت های ویژه
Introduction:The assessment of intravascular volume in severely traumatized patients or patients admitted in ICU is very essential. At present the accurate method for estimating the intravascular volume requirement is by measuring the CVP which is an invasive method. The measurement of IVC diameter by ultrasound has been suggested as an easily available and simple method for measuring the intra...
متن کاملThe potential value of intravascular ultrasound imaging in diagnosis of aortic intramural hematoma
OBJECTIVE To evaluate the potential value of intravascular ultrasound (IVUS) imaging in the diagnosis of aortic intramural hematoma (AIH). METHODS From September 2002 to May 2005, a consecutive series of 15 patients with suspected aortic dissection (AD) underwent both IVUS imaging and spiral computed tomography (CT). Six patients diagnosed as acute type B AIH by CT or IVUS composed the presen...
متن کاملManagement of anesthesia in a patient with ruptured abdominal aortic aneurysm: A case report
Introduction: Abdominal aortic aneurysm is a multifactorial condition which associated with aging and atherosclerosis. During aneurysm surgery, hypotension after aortic clamp removing occure commonly that require specific treatments. This case report showes administration of blood and hemodynamic control methods after aortic unclumping during aortic aneurysm surgery. Patient: A 75–years-o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Revista espanola de cardiologia
دوره 63 5 شماره
صفحات -
تاریخ انتشار 2010