The role of haemorrhage and exudate detection in automated grading of diabetic retinopathy.

نویسندگان

  • Alan D Fleming
  • Keith A Goatman
  • Sam Philip
  • Graeme J Williams
  • Gordon J Prescott
  • Graham S Scotland
  • Paul McNamee
  • Graham P Leese
  • William N Wykes
  • Peter F Sharp
  • John A Olson
چکیده

BACKGROUND/AIMS Automated grading has the potential to improve the efficiency of diabetic retinopathy screening services. While disease/no disease grading can be performed using only microaneurysm detection and image-quality assessment, automated recognition of other types of lesions may be advantageous. This study investigated whether inclusion of automated recognition of exudates and haemorrhages improves the detection of observable/referable diabetic retinopathy. METHODS Images from 1253 patients with observable/referable retinopathy and 6333 patients with non-referable retinopathy were obtained from three grading centres. All images were reference-graded, and automated disease/no disease assessments were made based on microaneurysm detection and combined microaneurysm, exudate and haemorrhage detection. RESULTS Introduction of algorithms for exudates and haemorrhages resulted in a statistically significant increase in the sensitivity for detection of observable/referable retinopathy from 94.9% (95% CI 93.5 to 96.0) to 96.6% (95.4 to 97.4) without affecting manual grading workload. CONCLUSION Automated detection of exudates and haemorrhages improved the detection of observable/referable retinopathy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Costs and consequences of automated algorithms versus manual grading for the detection of referable diabetic retinopathy.

AIMS To assess the cost-effectiveness of an improved automated grading algorithm for diabetic retinopathy against a previously described algorithm, and in comparison with manual grading. METHODS Efficacy of the alternative algorithms was assessed using a reference graded set of images from three screening centres in Scotland (1253 cases with observable/referable retinopathy and 6333 individua...

متن کامل

Morphological Exudate Detection in Retinal Images using PCA-based Optic Disc Removal

Diabetic retinopathy lesion detection such as exudate in fundus image of retina can lead to early diagnosis of the disease. Retinal image includes dark areas such as main blood vessels and retinal tissue and also bright areas such as optic disk, optical fibers and lesions e.g. exudate. In this paper, a multistage algorithm for the detection of exudate in foreground is proposed. The algorithm se...

متن کامل

Automated grading for diabetic retinopathy: a large-scale audit using arbitration by clinical experts.

BACKGROUND/AIMS Automated grading software has the potential to reduce the manual grading workload within diabetic retinopathy screening programmes. This audit was undertaken at the request of Scotland's National Diabetic Retinopathy Screening Collaborative to assess whether the introduction of automated grading software into the national screening programme would be safe, robust and effective....

متن کامل

Assessment of Automated Disease Detection in Diabetic Retinopathy Screening Using Two-Field Photography

AIM To assess the performance of automated disease detection in diabetic retinopathy screening using two field mydriatic photography. METHODS Images from 8,271 sequential patient screening episodes from a South London diabetic retinopathy screening service were processed by the Medalytix iGrading™ automated grading system. For each screening episode macular-centred and disc-centred images of ...

متن کامل

Automated detection of fundus photographic red lesions in diabetic retinopathy.

PURPOSE To compare a fundus image-analysis algorithm for automated detection of hemorrhages and microaneurysms with visual detection of retinopathy in patients with diabetes. METHODS Four hundred fundus photographs (35-mm color transparencies) were obtained in 200 eyes of 100 patients with diabetes who were randomly selected from the Welsh Community Diabetic Retinopathy Study. A gold standard...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 94 6  شماره 

صفحات  -

تاریخ انتشار 2010