The tensile strength of uterosacral ligament sutures: a comparison of vaginal and laparoscopic techniques.

نویسندگان

  • Patrick J Culligan
  • John R Miklos
  • Miles Murphy
  • Roger Goldberg
  • Carol Graham
  • Robert D Moore
  • Meg Hainer
  • Michael H Heit
چکیده

OBJECTIVE To compare the tensile strength of two approaches for uterosacral ligament suturing using a cadaver model. METHODS In 12 unembalmed cadavers, four polytetrafluoroethylene sutures were placed through the uterosacral ligaments. In each cadaver, two sutures were placed laparoscopically, and two more were placed vaginally. A single, experienced surgeon placed all laparoscopic sutures (n = 23), and another experienced surgeon placed all vaginal sutures (n = 22). A blinded team of investigators measured the distance from each suture to the ipsilateral ischial spine; determined whether any sutures incorporated ureters, viscera, or large vessels; and then passed the sutures through an apical vaginal incision. Using a hand-held tensiometer, progressive tensile load was then applied to these sutures along the axis of the vagina until they either broke or were completely dislodged from the ligaments. RESULTS The average peak tension required to break or dislodge the sutures was 26.2 +/- 8.8 psi (laparoscopic) and 22.5 +/- 7.4 psi (vaginal) (P =.14, 95% confidence interval [CI] -1.2, 8.6). The average force required for suture breakage (n = 28) was 28 +/- 7 psi, and the average force applied when ligament failure occurred (n = 17) was 18.5 +/- 6 psi (P <.001, 95% CI -13.8, -5.2). The average distance from a laparoscopic or vaginal suture to the ipsilateral ischial spine was 19.1 +/- 7 mm and 17.4 +/- 6 mm, respectively (P =.46, 95% CI -3.0, 6.4). None of the sutures from either technique were found to incorporate a visceral structure, ureter, or great vessel. CONCLUSION These suturing techniques appear to be equal in tensile strength.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robotic Assisted Laparoscopic Apical Suspension. Description of a 4 Points Technique (RALAS-4): First Case Reported

The uterosacral ligaments (UTSL), together with the cardinal ligament (CL), hold the upper vagina and cervix over the levator plate. These 2 ligaments provided 4 points support at the apex. Here we describe our surgical technique of robotic assisted laparoscopic apical suspension (RALAS) using nonabsorbable sutures and describe a new 4 points technique (RALAS-4). 73year-old Caucasian woman, gra...

متن کامل

Tensile strength of the medial patellofemoral ligament before and after repair or reconstruction.

The tensile strength of the medial patellofemoral ligament (MPFL), and of surgical procedures which reconstitute it, are unknown. Ten fresh cadaver knees were prepared by isolating the patella, leaving only the MPFL as its attachment to the medial femoral condyle. The MPFL was either repaired by using a Kessler suture or reconstructed using either bone anchors or one of two tendon grafting tech...

متن کامل

Severe Pelvic Organ Prolapse with Large Vaginal Mucosal Defect Underwent Laparoscopic Shull’s Uterosacral Ligament Colpo-Suspension and TVM Operation by Two Stage Surgery

A 75-year-old woman complained of anuria and a sense of discomfort with severe pelvic organ prolapse (POP). We planned tension-free vaginal mesh (TVM) surgery after curing mucosal defects and completing treatment for diabetes mellitus. Anuria and pyelonephritis relapsed repeatedly due to the failure of ring pessary therapy. Surgical treatment was required emergently. We performed a total laparo...

متن کامل

Does round Ligament Fixation in Addition to a Simplified Uterosacral Ligament Suspension of the Vaginal Vault Improve the Functional Outcome after Vaginal Hysterectomy in Patients with Pelvic Organ Prolapse?

Hypothesis / aims of study Despite increase in popularity of uterus preserving techniques, vaginal hysterectomy is still a common option in the surgical treatment of uterine prolapse. However, in pelvic organ prolapse (POP) special attention has to be paid to a sufficient suspension of the vaginal vault in order to prevent recurrence of descent and to protect possibly additional repair of the v...

متن کامل

I-59: Diagnostic Accuracy of Physical Examination,Transvaginal Sonography, RectalEndoscopic Sonography, and Magnetic ResonanceImaging to Diagnose Deep InfiltratingEndometriosis

Background: To compare the value of physical examination, transvaginal sonography (TVS), rectal endoscopic sonography (RES), and magnetic resonance imaging (MRI) for the assessment of different locations of deep infiltrating endometriosis (DIE). Materials and Methods: Ninety-two consecutive patients with clinical evidence of pelvic endometriosis. Physical examination, TVS, RES, and MRI, perform...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Obstetrics and gynecology

دوره 101 3  شماره 

صفحات  -

تاریخ انتشار 2003