Electronic Returnless Fuel System Fault Diagnosis and Isolation: A Data-Driven Approach

نویسندگان

  • Bharath Pattipati
  • Krishna Pattipati
  • Youssef A. Ghoneim
  • Mark Howell
  • Mutasim Salman
چکیده

The Electronic Return-less Fuel System (ERFS) manages the delivery of fuel from the fuel tank to the engine. The pressure in the fuel line is electronically controlled by the fuel system control module by speeding up or slowing down the fuel pump. This allows the system to efficiently control the amount of fuel provided to the engine when compared to vehicles equipped with a standard fuel system wherein the fuel pump continuously runs at full speed. A failure in the fuel system that impacts the ability to deliver fuel to the engine will have an immediate effect on system performance. Consequently, improved reliability and availability, and reduction in the number of walk-home situations require efficient fault detection, isolation and prognosis of the ERFS system. This paper develops and implements data-driven fault detection, isolation and severity estimation algorithms for the ERFS. The HIL Fuel System Rig and a Chevrolet Silverado truck were used to collect and analyze the fuel system behavior under different fault conditions. Several data-driven classifiers, such as support vector machines, Knearest Neighbor, Discriminant analysis, Bayes classifier, Partialleast squares, Quadratic and Linear classifiers, were implemented on a limited set of data for both training and testing. Regression techniques, such as Partial least squares regression and Principle component regression, are used to estimate the severity of faults. The resulting solution approach has the potential to be applicable to a wide variety of systems, ranging from automobiles to aerospace systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PEM Fuel Cell System Robust LPV model-based Fault Diagnosis

In this paper, the problem of robust fault diagnosis in a PEM Fuel Cell (PEM FC) system is addressed. Fault detection is based on a LPV interval observer able to face the variations of parameters with the operating while preserving the linear structure of the model. At the same time, this approach addresses the robustness problem against modeling uncertainty included as unknown parameters whose...

متن کامل

Data-driven fault diagnosis and robust control: Application to PEM fuel cell systems

A data-driven methodology that includes the unfalsified control concept in the framework of fault diagnosis and isolation (FDI) and fault-tolerant control (FTC) is presented. The selection of the appropriate controller from a bank of controllers in a switching supervisory control setting is performed by using an adequate FDI outcome. By combining simultaneous on-line performance assessment of m...

متن کامل

An LPV Approach to Sensor Fault Diagnosis of Robotic Arm

One of the major challenges in robotic arms is to diagnosis sensor fault. To address this challenge, this paper presents an LPV approach. Initially, the dynamics of a two-link manipulator is modelled with a polytopic linear parameter varying structure and then by using a descriptor system approach and a robust design of a suitable unknown input observer by means of pole placement method along w...

متن کامل

Data-Driven Adaptive Observer for Fault Diagnosis

This paper presents an approach for data-driven design of fault diagnosis system. The proposed fault diagnosis scheme consists of an adaptive residual generator and a bank of isolation observers, whose parameters are directly identified from the process data without identification of complete process model. To deal with normal variations in the process, the parameters of residual generator are ...

متن کامل

Robust Model- Based Fault Detection and Isolation for V47/660kW Wind Turbine

In this paper, in order to increase the efficiency, to reduce the cost and to prevent the failures of wind turbines, which lead to an extensive break down, a robust fault diagnosis system is proposed for V47/660kW wind turbine operated in Manjil wind farm, Gilan province, Iran. According to the acquired data from Iran wind turbine industry, common faults of the wind turbine such as sensor fault...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013