Influence of patient's physiologic factors and immobilization choice with stereotactic body radiotherapy for upper lung tumors

نویسندگان

  • Terence T. Sio
  • Andrew R. Jensen
  • Robert C. Miller
  • Luis E. Fong de los Santos
  • Christopher L. Hallemeier
  • Nathan R. Foster
  • Sean S. Park
  • Heather J. Bauer
  • Kenneth Chang
  • Yolanda I. Garces
  • Kenneth R. Olivier
چکیده

The purpose of the present study was to compare the impact of pulmonary function, body habitus, and stereotactic body radiation therapy (SBRT) immobilization on setup and reproducibility for upper lung tumor. From 2008 through 2011, our institution's prospective SBRT database was searched for patients with upper lung tumors. Two SBRT immobilization strategies were used: full-length BodyFIX and thermoplastic S-frame. At simulation, free-breathing, four-dimensional computed tomography was performed. For each treatment, patients were set up to isocenter with in-room lasers and skin tattoos. Shifts from initial and subsequent couch positions with cone-beam computed tomography (CBCT) were analyzed. Accounting for setup uncertainties, institutional tolerance of CBCT-based shifts for treatment was 2, 2, and 4 mm in left-right, anterior-posterior, and cranial-caudal directions, respectively; shifts exceeding these limits required reimaging. Each patient's pretreatment pulmonary function test was recorded. A multistep, multivariate linear regression model was performed to elucidate intervariable dependency for three-dimensional calculated couch shift parameters. BodyFIX was applied to 76 tumors and S-frame to 17 tumors. Of these tumors, 41 were non-small cell lung cancer and 15 were metastatic from other sites. Lesions measured < 1 (15%), 1.1 to 2 (50%), 2.1 to 3 (25%), and > 3 (11%) cm. Errors from first shifts of first fractions were significantly less with S-frame than BodyFIX (p < 0.001). No difference in local control (LC) was found between S-frame and BodyFIX (p = 0.35); two-year LC rate was 94%. Multivariate modeling confirmed that the ratio of forced expiratory volume in the first second of expiration to forced vital capacity, body habitus, and the immobilization device significantly impacted couch shift errors. For upper lung tumors, initial setup was more consistent with S-frame than BodyFIX, resulting in fewer CBCT scans. Patients with obese habitus and poor lung function had more SBRT setup uncertainty; however, outcome and probability for LC remained excellent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates

Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Stereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters

Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...

متن کامل

A study on the accuracy of motion tracking of thoracic tumors at radiotherapy with external surrogates

Introduction: In radiotherapy with external surrogates, exact information of tumor position is one of the key factors that improves treatment delivery. Many dynamic tumors in thorax region of patient move mainly due to respiration and are known as intra-fractional motion error that must be compensated, as well. One of clinical strategy is using Stereotactic Body Radiation Thera...

متن کامل

Investigation of lung normal tissue doses in lung tumors radiation therapy using both gated and conventional radiotherapy

Introduction: In radiation therapy of lung tumors, respiratory motion causes target moving, so a larger margin is needed to cover the clinical target volume (CTV). With the margin increasing, a larger volume of normal tissue will be exposed to high-dose.  In this study, dosimetric parameters of normal lung tissue were compared between gated and conventional radiotherapy (RT), u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014