Test-retest variability of multifocal visual evoked potential and SITA standard perimetry in glaucoma.
نویسندگان
چکیده
PURPOSE To investigate the test-retest variability of multifocal visual evoked potential (mfVEP) and threshold perimetry in glaucoma, and to examine the relationship between the two techniques. METHODS Data were recorded using the AccuMap mfVEP and SITA standard program of the Humphrey Field Analyzer. Data were obtained twice within a 4-week period from both eyes of 74 patients with varying amounts of glaucomatous visual field loss. The number of defective test locations (those falling beyond a given probability value of being normal) were calculated for mfVEP and SITA, using databases incorporated within the instruments software. Reliability measures and test times were recorded along with patient test preference. RESULTS Both tests showed a large degree of test-retest variability in the number of defective test locations (95% limits of agreement for mfVEP and SITA being 13.39 and 9.88, respectively). A "fair to moderate" degree of spatial agreement was found between mfVEP and SITA. The number of mfVEP defective locations was dependent on the signal amplitude. No relationship was found between test-retest variability and the reliability indices for either test. The mean time taken to perform mfVEP and SITA standard was 33 and 20 minutes, respectively, and 73 of the 74 patients preferred the mfVEP test. CONCLUSIONS Test-retest variability was found to be slightly greater for mfVEP. The processing of mfVEP signals needs to be changed to remove the relationship between the number of defective locations and signal amplitude. The majority of patients preferred mfVEP to conventional perimetry although mfVEP takes longer to perform.
منابع مشابه
Repeatability of automated perimetry: a comparison between standard automated perimetry with stimulus size III and V, matrix, and motion perimetry.
PURPOSE Standard automated perimetry (SAP) shows a marked increase in variability in damaged areas of the visual field. This study was conducted to test the hypothesis that larger stimuli are associated with more uniform variability, by investigating the retest variability of four perimetry tests: standard automated perimetry size III (SAP III), with the SITA standard strategy; SAP size V (SAP ...
متن کاملVariability of visual field measurements is correlated with the gradient of visual sensitivity
Conventional static automated perimetry provides important clinical information, but its utility is limited by considerable test-retest variability. Fixational eye movements during testing could contribute to variability. To assess this possibility, it is important to know how much sensitivity change would be caused by a given eye movement. To investigate this, we have evaluated the gradient, t...
متن کاملFrequency-doubling technology perimetry and multifocal visual evoked potential in glaucoma, suspected glaucoma, and control patients
INTRODUCTION The gold standard in functional glaucoma evaluation is standard automated perimetry (SAP). However, SAP depends on the reliability of the patients' responses and other external factors; therefore, other technologies have been developed for earlier detection of visual field changes in glaucoma patients. The frequency-doubling perimetry (FDT) is believed to detect glaucoma earlier th...
متن کاملDevelopment and evaluation of a contrast sensitivity perimetry test for patients with glaucoma.
PURPOSE To design a contrast sensitivity perimetry (CSP) protocol that decreases variability in glaucomatous defects while maintaining good sensitivity to glaucomatous loss. METHODS Twenty patients with glaucoma and 20 control subjects were tested with a CSP protocol implemented on a monitor-based testing station. In the protocol 26 locations were tested over the central visual field with Gab...
متن کاملEvaluation of Hemifield Sector Analysis Protocol in Multifocal Visual Evoked Potential Objective Perimetry for the Diagnosis and Early Detection of Glaucomatous Field Defects
PURPOSE Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, an...