Detection of Mechanical Damage Using the Magnetic Flux Leakage Technique

نویسندگان

  • L. Clapham
  • V. Babbar
چکیده

Since magnetism is strongly stress dependent, Magnetic Flux Leakage (MFL) inspection tools have the potential to locate and characterize mechanical damage in pipelines. However, MFL application to mechanical damage detection faces hurdles which make signal interpretation problematic: 1) the MFL signal is a superposition of geometrical and stress effects, 2) the stress distribution around a mechanically damaged region is very complex, consisting of plastic deformation and residual (elastic) stresses, 3) the effect of stress on magnetic behaviour is not well understood. This paper summarizes recent results of experimental and modeling studies of MFL signals resulting from mechanical damage. In experimental studies, mechanical damage was simulated using a tool and die press to produce dents of varying depths in plate samples. MFL measurements were made before and after selective stressrelieving heat treatments. These annealing treatments enabled the stress and geometry components of the MFL signal to be separated. In general, geometry effects scale with dent depth and tend to dominate in deep dents, while stress contribution to the MFL signals is relatively constant and is more significant for shallow dents. The influence of other parameters such as flux density and topside/bottomside inspection was also quantified. In the finite element analysis work, stress was incorporated by modifying the magnetic permeability in the residual stress regions of the modeled dent. Both stress and geometry contributions to the MFL signal were examined separately. Despite using a number of simplifying assumptions, the modeled results matched the experimental results very closely, and were used to aid in interpretation of the MFL signals. 1.0 Introduction: The most common cause of pipeline failure in North America is mechanical damage: denting or gouging of the pipeline by a third party or local deformation created by rocks or ground movement. In many cases these fail under load or are detected immediately. In other cases they may remain undetected for years, with the local damage acting as sites for further corrosion or cracking and potentially leading to a delayed failure. Intelligent magnetic flux leakage (MFL) tools are used extensively in pipelines for in-line corrosion inspection. Recently the industry has turned its attention to using MFL to detect and quantify mechanical damage in these pipes. Since typically there is little or no metal loss with mechanical damage, MFL signals arise from a complex combination of dent geometry and stresses in the pipe wall. These MFL signals are very difficult to interpret, and even more difficult to predict. This paper summarizes recent experimental and modeling results of MFL signals resulting from mechanical damage. Samples were dented, tested, and then subsequently heat treated to remove residual stress contributions, effectively allowing the ‘geometry’ and ‘residual stress’ contributions of the MFL signals to be separated. The experimental results were compared with MFL signal predictions from magnetic FEA models into which the effects of stress and geometry were incorporated. 1.1 The MFL technique: A schematic diagram of an MFL detector is shown in Figure 1. High strength Nd-Fe-B permanent magnets produce a magnetic field in the pipe wall. When a defect such as a pit is present , some of the flux is forced (or "leaks") into the surrounding air. As the tool moves along the pipe, the sensor (typically a coil or hall probe) passes over this leakage flux region and an MFL signal is registered. In our experimental laboratory system the MFL magnet is stationary and (for this study) could be configured to produce a range of pipe wall flux densities up to 1.8T. The two flux densities examined were 1.4T and 1.8T – these correspond to the flux densities produced in pipe walls by moderate and high flux density inspection tools. The sensor uses a Hall probe as a sensing element, attached to the arm of an XY plotter, allowing a 40mmx40mm area to be scanned above a defect region at 1mm intervals. It can be oriented to measure either the axial, radial or circumferential components of the leakage flux signal, and is connected though an amplifier to a PC-based data acquisition system. In this paper, only the radial MFL signal will be considered. As an example, Figure 2 shows a typical surface and contour plot of the radial MFL signal from a 14mm diameter, 50% penetration pit in a pipeline section. 1.2 Sample preparation and testing: Samples of 0.12" (3mm) and 0.24” (6mm) thick plate were subjected to controlled denting using a compression testing machine. Prior to denting, the samples were stress relieved at 500C for three hours to remove any pre-existing residual stresses. Dents were produced using a cylindrical tool with a rounded tip, which was pushed into the plate. A die containing a larger hole was located below the tool. Dents of two different diameters were produced. For ease of reference these were termed ‘small’ and ‘large’ dents, defined as below: Small dents: A 20mm diameter cylindrical tool was used to produce these dents in 0.12” (3mm) thick plate samples. Dents from 0.02" to 0.12" (0.5mm deep to 3mm deep) were produced, with varying diameters from 0.14" to 0.43" (3.5mm to 11mm). Large dents: A 40 mm diameter cylindrical tool was used to produce dents of approximately 1-1.5” diameter (2536mm) in the 0.24” (6mm) plate samples. Dent depths ranged from 0.12” – 0.35” (3 – 8mm). 1.3 Heat treatments: Our earlier work [2] showed that the effect of residual stress on MFL signals can be removed using ‘traditional’ stress-relieving heat treatments. Therefore, in the present study, annealing was used to remove residual stress effects on the MFL signal, leaving only the MFL geometry component. 2.0 Results: After denting, MFL measurements were made on both sides of the dented sample. The concave side, termed the ‘topside’ of the sample, was the easiest side to measure – a thin sheet of plastic is placed over the ‘hole’ after which the hall probe moves essentially on a flat plane. The convex side, termed the ‘bottomside’ was more difficult to measure since the sensor must follow the dent contour. The bottomside results are of greater practical interest, however, since this is the side accessed in a typical pipeline inspection scenario. A full set of measurements were taken for both topside and bottomside orientations. For the sake of brevity, however, in the present paper we will focus primarily on the bottomside results, since these are most industrially relevant. Finally, in these bottomside measurements the sensor was fixed to always be parallel to the original plane of the sample (rather than the dent profile) as it traveled over the dent. 2.1 Small dents: bottomside MFL contour plots, before and after annealing: Figure 3 shows MFL signal contour plots (radial component) for small dents from 1.0mm deep up to 3mm deep (0.5mm was also tested but is essentially similar to the 1mm deep signal). MFL signals are shown prior to and after stress-relief annealing, for a flux density of 1.8T. Before annealing, (Figure 3 – Preanneal) MFL signals exhibit the following features: 1) a centre peak region which, for shallow dents, is similar to that seen for a typical corrosion pit (see Figure 2) and 2) four ‘shoulder peaks’ at approximately 45 to the applied field direction. As the dents become deeper another fairly broad central peak develops between the two shoulder peaks – giving the appearance that the shoulder peaks are ‘growing together’. After stress relief annealing (Figure 3 – post anneal) the most important result is that the ‘shoulder’ peaks essentially disappear, except in the deepest dent cases where some vestige of the shoulder peak signals still remain. Conversely, the centre peaks remain, as do the broad central peaks that formed between the shoulder peaks as the dents become deeper. Although the form of these centre peaks does not change, analysis of their heights indicate that they are slightly lower than before annealing. 2.2 Large dents: bottomside MFL contour plots, before and after annealing, B=1.8T: Figure 4 shows MFL signal contour plots (radial component) for the large dent samples, with dents from 3mm to 8mm depths. In comparison with the small dent results of Figure 3, the deeper dent signals display similar features but are generally larger in scale as expected. As with the smaller dents, the central peaks remains largely unaffected by annealing, while the shoulder peaks disappear or shrink considerably. Both the small (Fig 3) and large (Fig 4) dent results exhibit similar patterns before and after annealing. We are able to conclude from these results that the central MFL peaks are largely due to the dent geometry, although these peaks experience a size reduction with annealing which suggests a small stress contribution. The shoulder peaks, however, appear to be almost entirely stress-related, since they are diminished significantly, and often completely, during stress-relief annealing. 2.3 Comparison of topside and bottomside MFL contour plots: Figure 5 shows a example comparison of topside MFL versus bottomside MFL signal contour plots. Results are for large dents, 5.0mm deep, both pre and post-anneal. The background flux density is B=1.8T. Interestingly, there is little difference between the results, except in overall signal magnitude. All other dent geometries exhibited the same similarities between topside and bottomside MFL signals. Figure 5. Comparison of MFL radial signals from the topside (top) and bottomside (bottom) of the dented sample, both before and after annealing. 2.4 MFL peak-to-peak comparisons: The MFLpp signal was also measured for all samples, however this only reflected the size of the main centre peak (a further study of the shoulder peak height is currently underway). Figure 6 and Figure 7 show bottomside and topside MFLpp results respectively, for the large dent samples. In both figures, (a) represents the low flux density results and (b) the high flux density case. The two sets of data on each graph indicate 1) the pre-annealing state where the MFL signal is comprised of both geometry and stress contributions, and 2) the post annealing state where the signal is predominately geometry induced. Overall, these plots indicate that the magnitude of the bottomside signals (Fig 6) tends to generally be higher than those of the topside (Figure 7), particularly at higher flux densities (figs 6(b) and 7(b)). Furthermore, the topside signals tend to be more significantly affected by stress, since the ‘gap’ between the topside curves is greater than that for the bottomside MFL. Finally, comparing flux density affects, the stress contribution to the MFL signal is at low flux densities (Figure 6(a) and Figure 7(a)) tends to be generally higher than at high flux densities. Overall, these plots indicate that the magnitude of the bottomside signals (Fig 6) tends to generally be higher than those of the topside (Figure 7), particularly at higher flux densities (figs 6(b) and 7(b)). Furthermore, the topside signals tend to be more significantly affected by stress, since the ‘gap’ between the topside curves is greater than that for the bottomside MFL. Finally, comparing flux density affects, the stress contribution to the MFL signal is at low flux densities (Figure 6(a) and Figure 7(a)) tends to be generally higher than at high flux

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Theory and Application of Magnetic Flux Leakage Pipeline Detection

Magnetic flux leakage (MFL) detection is one of the most popular methods of pipeline inspection. It is a nondestructive testing technique which uses magnetic sensitive sensors to detect the magnetic leakage field of defects on both the internal and external surfaces of pipelines. This paper introduces the main principles, measurement and processing of MFL data. As the key point of a quantitativ...

متن کامل

DAMAGE DETECTION IN THIN PLATES USING A GRADIENT-BASED SECOND-ORDER NUMERICAL OPTIMIZATION TECHNIQUE

The purpose of the present study is the damage detection in the thin plates in terms of the wide application of such structures in various branches of engineering such as structural, mechanical, aerospace, shipbuilding, etc. using gradient-based second-order numerical optimization techniques. The technique used for optimization in this study is the second-order Levenberg-Marquardt algorithm (SO...

متن کامل

Magnetic Flux Leakage Sensing and Artificial Neural Network Pattern Recognition-Based Automated Damage Detection and Quantification for Wire Rope Non-Destructive Evaluation

In this study, a magnetic flux leakage (MFL) method, known to be a suitable non-destructive evaluation (NDE) method for continuum ferromagnetic structures, was used to detect local damage when inspecting steel wire ropes. To demonstrate the proposed damage detection method through experiments, a multi-channel MFL sensor head was fabricated using a Hall sensor array and magnetic yokes to adapt t...

متن کامل

Experimental Study on the Effect of Magnetic Field on Critical Heat Flux of Ferrofluid Flow Boiling in a Vertical Tube

In the present work, the critical heat flux measurements were performed for the subcooled flow boiling of pure water and magnetic nanofluids (i.e., water + 0.01 and 0.1 vol.% Fe‌‌3O4) in a vertical tube. The effect of applying an external magnetic field on the CHF variation was studied experimentally as well. The obtained results indicated that the subcooled flow boiling CHF in the vertical tub...

متن کامل

An Experimental Investigation of Magnetized Water Effect on Formation Damage

In oil industries, water injection into oil reservoirs for pressure maintenance, oil displacement, and oil recovery is a common technique. Formation damage during water injection is a major problem in this process. Formation damage from the incompatibility of formation water (FW) and injection water (IW) causes a reduction in the permeability around the injection wells. Therefore, it is necessa...

متن کامل

Structural Health Monitoring System for Deepwater Risers with Vortex-induced Vibration: Nonlinear Modeling, Blind Identification Fatigue/Damage Estimation and Local Monitoring using Magnetic Flux Leakage

Structural Health Monitoring System for Deepwater Risers with Vortex-induced Vibration: Nonlinear Modeling, Blind Identification Fatigue/Damage Estimation and Local Monitoring using Magnetic Flux Leakage

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004