Neutrons from fragmentation of light nuclei in tissue-like media: a study with the GEANT4 toolkit.

نویسندگان

  • Igor Pshenichnov
  • Igor Mishustin
  • Walter Greiner
چکیده

We study energy deposition by light nuclei in tissue-like media taking into account nuclear fragmentation reactions, in particular, production of secondary neutrons. The calculations are carried out within a Monte Carlo model for heavy-ion therapy (MCHIT) based on the GEANT4 toolkit. Experimental data on depth-dose distributions for 135-400 A MeV (12)C and (18)O beams are described very well without any adjustment of the model parameters. This gives confidence in successful use of the GEANT4 toolkit for MC simulations of cancer therapy with beams of light nuclei. The energy deposition due to secondary neutrons produced by (12)C and (20)Ne beams in a (40-50 cm)(3) water phantom is estimated to be 1-2% of the total dose, that is only slightly above the neutron contribution (approximately 1%) induced by a 200 MeV proton beam.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The response of Geant4 hadronic models to the study of neutrons produced in proton irradiation to the light materials

Neutron is one of the products of the interaction of high energy protons with light nuclei. Using computational Monte Carlo codes, it is possible to calculate and predict the neutron spectrum, neutron flux, and doses by simulating the system. But the use of different hadronic models in this process can influence the results of these calculations. In this research, the response of the four hadro...

متن کامل

MCHIT - Monte Carlo model for proton and heavy-ion therapy

We study the propagation of nucleons and nuclei in tissue-like media within a Monte Carlo Model for Heavy-ion Therapy (MCHIT) based on the GEANT4 toolkit (version 8.2). The model takes into account fragmentation of projectile nuclei and secondary interactions of produced nuclear fragments. Model predictions are validated with available experimental data obtained for water and PMMA phantoms irra...

متن کامل

An investigation of neutron direct damages at energies of 0.1-2 MeV on the DNA molecules with atomic structure deduced using Geant4 toolkit

This study proposes a method to estimate RBE of fast neutrons using Monte Carlo simulations. This approach is based on the combination of an atomic resolution DNA geometrical model and Monte Carlo simulations for tracking particles. Atomic positions were extracted from the Protein Data Bank. The GEANT4 code was used for tracking the secondary particles generated by fast neutrons during their in...

متن کامل

beams: a study with the GEANT4 toolkit

We study the spatial distributions of β-activity produced by therapeutic beams of He and C ions in various tissue-like materials. The calculations were performed within a Monte Carlo model for Heavy-Ion Therapy (MCHIT) based on the GEANT4 toolkit. The contributions from positronemitting nuclei with T1/2 > 10 s, namely 10,11C, N, 14,15O, 17,18F and P, were calculated and compared with experiment...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 50 23  شماره 

صفحات  -