Tissue Engineering Applied to the Retinal Prosthesis: Neurotrophin-Eluting Polymeric Hydrogel Coatings.
نویسندگان
چکیده
Several groups are developing visual prostheses to aid patients with vision loss. While these devices have shown some success in the clinic, they are severely limited by poor resolution, and in many cases have as few as 15 electrodes. Pixel density is poor because high stimulation thresholds require large electrodes to minimize charge density that would otherwise damage the electrode and tissue. A significant contributor to high stimulation threshold requirements is poor biocompatibility. We investigated the application of one system popular in tissue engineering, drug-releasing hydrogels, as a mechanism to improve the tissue-electrode interface. Hydrogels studied (i.e., PEGPLA photocrosslinkable polymers) released neurotrophic factors (i.e., BDNF) known to promote neuron survival and neurite extension in the retina. Hydrogels were examined in co-culture with retinal explants for 7 and 14 days, at which time neurite extension and neurite density was measured. Neurite extension was enhanced in samples exposed to BDNF-releasing hydrogels at 7 days; however, these increases were absent by day 14 suggesting declining drug release. Thus, PEGPLA hydrogels are excellent candidates for short-term (< 14 day) acute release of therapeutic factors in the retina, but will require additional modifications for application with neural prostheses. Additionally, these results suggest that the effects of neurotrophic factors are short-lived in the absence of additional support cues, and tissue engineering systems employing such factors may only produce transient benefits to the patient.
منابع مشابه
Hydrogel–Electrospun Fiber Mat Composite Coatings for Neural Prostheses
Achieving stable, long-term performance of implanted neural prosthetic devices has been challenging because of implantation related neuron loss and a foreign body response that results in encapsulating glial scar formation. To improve neuron-prosthesis integration and form chronic, stable interfaces, we investigated the potential of neurotrophin-eluting hydrogel-electrospun fiber mat (EFM) comp...
متن کاملPolylysine-modified PEG-based hydrogels to enhance the neuro-electrode interface.
Neural prostheses are a promising technology in the treatment of lost neural function. However, poor biocompatibility of these devices inhibits the formation of a robust neuro-electrode interface. Several factors including mechanical mismatch between the device and tissue, inflammation at the implantation site, and possible electrical damage contribute to this response. Many researchers are inv...
متن کاملEffect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis
This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...
متن کاملEffect of Plasma Electrolytic Oxidation Process as a Pretreatment on Corrosion Resistance of Polymeric Coatings Applied on Mg Alloy
In this study, Plasma Electrolytic Oxidation (PEO) at three frequencies of 500, 1000 and 3000 Hz was applied on Mg surface and the effect of PEO surface preparation on protective behavior of three types of epoxy, fusion bond epoxy (FBE) and polyurethane coatings was investigated. The microstructural and protective properties of PEO coatings were studied by SEM, potentiodynamic polarization and ...
متن کاملEffect of Plasma Electrolytic Oxidation Process as a Pretreatment on Corrosion Resistance of Polymeric Coatings Applied on Mg Alloy
In this study, Plasma Electrolytic Oxidation (PEO) at three frequencies of 500, 1000 and 3000 Hz was applied on Mg surface and the effect of PEO surface preparation on protective behavior of three types of epoxy, fusion bond epoxy (FBE) and polyurethane coatings was investigated. The microstructural and protective properties of PEO coatings were studied by SEM, potentiodynamic polarization and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Materials science & engineering. C, Materials for biological applications
دوره 28 3 شماره
صفحات -
تاریخ انتشار 2008