Development of a rapid Buffer-exchange system for time-resolved ATR-FTIR spectroscopy with the step-scan mode

نویسندگان

  • Yuji Furutani
  • Tetsunari Kimura
  • Kido Okamoto
چکیده

Attenuated total reflectance (ATR)-FTIR spectroscopy has been widely used to probe protein structural changes under various stimuli, such as light absorption, voltage change, and ligand binding, in aqueous conditions. Time-resolved measurements require a trigger, which can be controlled electronically; therefore, light and voltage changes are suitable. Here we developed a novel, rapid buffer-exchange system for time-resolved ATR-FTIR spectroscopy to monitor the ligand- or ion-binding re-action of a protein. By using the step-scan mode (time resolution; 2.5 ms), we confirmed the completion of the buffer-exchange reaction within ∼25 ms; the process was monitored by the infrared absorption change of a nitrate band at 1,350 cm(-1). We also demonstrated the anion-binding reaction of a membrane protein, Natronomonas pharaonis halorhodopsin (pHR), which binds a chloride ion in the initial anion-binding site near the retinal chromophore. The formation of chloride- or nitrate-bound pHR was confirmed by an increase of the retinal absorption band at 1,528 cm(-1). It also should be noted that low sample consumption (∼1 µg of protein) makes this new method a powerful technique to understand ligand-protein and ion-protein interactions, particularly for membrane proteins.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modification of Time-Resolved Step-Scan and Rapid-Scan FTIR Spectroscopy for Modulation Spectroscopy in the Frequency Range from Hz to kHz

Interleaved Rapid-Scan (continuous scan) and time-resolved Step-Scan techniques were modified in order to use these techniques for modulation experiments. The demodulation of the time-resolved spectra was done by software, replacing expensive Lock-In amplifiers. The new techniques lead to the same results compared to conventional Lock-In Step-Scan methods but show dramatically shortened measure...

متن کامل

Evaluation of Pre-Fixed Biological Tissues Preparation Methods for ATR-FTIR Biospectroscopy

Evaluation of Pre-Fixed Biological Tissues Preparation Methods for ATR-FTIR Biospectroscopy Fourier transform infrared (FTIR) spectroscopy in ATR (attenuated total reflection) mode is a powerful tool for studying biomedical samples, which can provide important structural information on the molecular composition. Currently, formalin fixation and paraffin preservation (FFPP) is the preferred sourc...

متن کامل

Identification and Quantification of Texture Soy Protein in A Mixture with Beef Meat Using ATR-FTIR Spectroscopy in Combination with Chemometric Methods

Meat, as an important source of protein, is one of the main parts of many people’s diet. Due toeconomic interests and thereupon adulteration, there are special concerns on its accurate labeling.In this study Fourier transform infrared (ATR-FTIR) spectroscopy combined with chemometrictechniques (principal component analysis (PCA), artificial neural networks (ANNs), and partial<...

متن کامل

Identification and Quantification of Texture Soy Protein in A Mixture with Beef Meat Using ATR-FTIR Spectroscopy in Combination with Chemometric Methods

Meat, as an important source of protein, is one of the main parts of many people’s diet. Due toeconomic interests and thereupon adulteration, there are special concerns on its accurate labeling.In this study Fourier transform infrared (ATR-FTIR) spectroscopy combined with chemometrictechniques (principal component analysis (PCA), artificial neural networks (ANNs), and partial<...

متن کامل

Fourier transform infrared (FTIR) and step-scan time-resolved FTIR spectroscopies reveal a unique active site in cytochrome caa3 oxidase from Thermus thermophilus.

Fourier transform infrared (FTIR) and step-scan time-resolved FTIR difference spectra are reported for the [carbonmonoxy]cytochrome caa(3) from Thermus thermophilus. A major C-O mode of heme a(3) at 1958 cm(-1) and two minor modes at 1967 and 1975 cm(-1) (7:1:1) have been identified at room temperature and remained unchanged in H(2)O/D(2)O exchange. The observed C-O frequencies are 10 cm(-1) hi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2013