Off-pump tricuspid valved stent implantation: the next step.
نویسندگان
چکیده
OBJECTIVES Off-pump transcatheter valved stent implantation could be a treatment option for patients suffering from symptomatic tricuspid regurgitation (TR) who are classified as inoperable. In this study, we present our recent short-term results of transventricular tricuspid valved stent implantation and compare different stent types for atrial anchorage. METHODS Fifteen pigs received a self-expandable valved stent implantation off-pump via a transventricular access. Successfully implanted pigs were observed over a period of 6 h (n = 9), 48 h (n = 1) and 4 weeks (n = 1). Haemodynamic and full transoesophageal echocardiographic (TOE) evaluations were done before, 1 h, 3 h (n = 11; all successfully implanted pigs), and 6 h (n = 9; acute group) after implantation. Nine days postimplantation, one pig received additional angiography, computed tomography (CT) and transthoracic echocardiography (TTE). Post-mortem, gross examination was conducted to analyse the stent position and deformation. In two pigs (48 h and 4 weeks survival) histological staining and immunohistochemistry of surrounding myocardium was performed. RESULTS The heart rate significantly increased in all pigs postimplantation from 66.8 ± 13.6 to 101.8 ± 24.6 bpm, whereas cardiac output and pressure levels remained unchanged. Orthotopic positioning was reproducibly achieved. TOE showed an efficient reduction of paravalvular leakages from a mean grade of 1.4 1 h postimplantation to a mean of 0.9 at 6 h postimplantation due to a special sealing pouch. The ratio early and late ventricular filling velocities remained constant and the valvular gradient across the valved stent stayed low during the observation period. Angiography, CT and TTE confirmed orthotopic positioning and mild grade of paravalvular leakage after 9 days (n = 1). Only mild TR was observed here. The ventricular part of the stent was deformed to an oval shape in 7 of 14 animals as shown via post-mortem examination. The surrounding tissue after 1 month (n = 1) showed normal morphology, without inflammation or calcification. CONCLUSION This study shows the feasibility of catheter-based replacement of the tricuspid valve by a valved stent in an off-pump procedure. The successive enhancements in this tricuspid valved stent design lead to a prototype being ready for mid- to long-term evaluations.
منابع مشابه
Tricuspid valved stent implantation: novel stent with a self-expandable super-absorbent polymer.
OBJECTIVE Trans-catheter aortic and pulmonary valve replacement procedures can result in favorable outcomes in selected patients. The aim of this study was to investigate the functioning of a novel self-expanding valved stent with super-absorbent polymer (SAP) for minimally invasive replacement of the tricuspid valve. METHODS A newly designed nitinol stent with SAP was specially designed for ...
متن کاملTransapical mitral valve implantation: the Lutter valve
The development of transcatheter techniques for treatment of severe mitral valve regurgitation in the beating heart is focus of recent research. An off-pump treatment technique poses great benefits, particularly for multimorbid patients, often being non-compliant to the gold standard treatment, being open heart surgery with use of a cardiopulmonary bypass. Thereto, two approaches are being fo...
متن کاملOff-bypass implantation of a self-expandable valved stent between inferior vena cava and right atrium.
A glutaraldehyde preserved valved bovine jugular xenograft mounted in a nitinol 'Z' stent, expandable from 7 to 28 mm of internal diameter, was evaluated in vitro (column of water developing a pressure of 45 mmHg and a mock loop including a pulsatile pump) and in vivo in five adult pigs with intra-vascular ultrasound to measure the inferior vena cava diameter via a retroperitoneal access. Throu...
متن کاملDouble-crowned valved stents for off-pump mitral valve replacement.
OBJECTIVE An animal model has been designed to assess the feasibility of off-pump mitral valve replacement using valved stents. METHODS Glutaraldehyde-preserved homograft was sutured inside a prosthetic tube (Dacron). Then, two self-expandable nitinol Z-stents were sutured on the external surface of the prosthesis in such a way to create two self-expanding crowns for fixation. In adult pigs a...
متن کاملIs it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults.
OBJECTIVES This study was designed to study the behavior of a stent deployed inside human stenotic aortic valves. BACKGROUND Endovascular valved stent (VS) implantation is a promising new therapy for patients with severe calcific aortic stenosis (AS). The precise characteristics of stent deployment in humans have been poorly studied so far. METHODS Thirty-five patients with severe AS were i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 45 3 شماره
صفحات -
تاریخ انتشار 2014