Results of the California Healthy Homes Indoor Air Quality Study of 2011-2013: impact of natural gas appliances on air pollutant concentrations.

نویسندگان

  • N A Mullen
  • J Li
  • M L Russell
  • M Spears
  • B D Less
  • B C Singer
چکیده

This study was conducted to assess the current impact of natural gas appliances on air quality in California homes. Data were collected via telephone interviews and measurements inside and outside of 352 homes. Passive samplers measured time-resolved CO and time-integrated NOX , NO2 , formaldehyde, and acetaldehyde over ~6-day periods in November 2011 - April 2012 and October 2012 - March 2013. The fraction of indoor NOX and NO2 attributable to indoor sources was estimated. NOX , NO2 , and highest 1-h CO were higher in homes that cooked with gas and increased with amount of gas cooking. NOX and NO2 were higher in homes with cooktop pilot burners, relative to gas cooking without pilots. Homes with a pilot burner on a floor or wall furnace had higher kitchen and bedroom NOX and NO2 compared to homes without a furnace pilot. When scaled to account for varying home size and mixing volume, indoor-attributed bedroom and kitchen NOX and kitchen NO2 were not higher in homes with wall or floor furnace pilot burners, although bedroom NO2 was higher. In homes that cooked 4 h or more with gas, self-reported use of kitchen exhaust was associated with lower NOX , NO2 , and highest 1-h CO. Gas appliances were not associated with higher concentrations of formaldehyde or acetaldehyde.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of H2S Content and Excess Air on Pollutant Emission in Sour Gas Flares

In sour gas flares,  content like any other components in inlet gas influences adiabatic flame temperature, which, in turn, impacts on the pollutant emission. Wherever flame temperature increases, the endothermic reaction between  and  is accelerated, which means higher  emission to the atmosphere. In this work, we developed an in-house MATLAB code to provide an environment for combustion calcu...

متن کامل

Evaluation of air pollutant concentrations and environmental parameters under normal condition and during novel Coronavirus pandemic, a case study in a hospital (2019-2020)

Background and Objective: Indoor air pollution in hospitals could be a serious health threat to the patients, medical staff, and visitors. In previous studies, the importance of paying attention to air quality during the Coronavirus pandemic has been proven. In this study, the effect of visiters' presence under normal conditions and the imposition of hospital restrictions at the time of pandemi...

متن کامل

An Innovative Method to Allocate Air-Pollution-Related Taxes, Using Aermod Modeling (case study: Besat Power Plant).

The present study applies the model of American Meteorological Society-Environmental Protection Agency Regulatory Model (AERMOD) to investigate NO2 emissions from Besat thermal power plant, which is fuelled by natural gas to function. Results indicate that the simulated concentration of NO2 based on AERMOD, does not exceed NO2 concentration limit, set by the Iranian Ambient Air Quality Standard...

متن کامل

An Innovative Method to Allocate Air-Pollution-Related Taxes, Using Aermod Modeling (case study: Besat Power Plant).

The present study applies the model of American Meteorological Society-Environmental Protection Agency Regulatory Model (AERMOD) to investigate NO2 emissions from Besat thermal power plant, which is fuelled by natural gas to function. Results indicate that the simulated concentration of NO2 based on AERMOD, does not exceed NO2 concentration limit, set by the Iranian Ambient Air Quality Standard...

متن کامل

Cooking Up Indoor Air Pollution: Emissions from Natural Gas Stoves

Cooking Up Indoor Air Pollution Emissions from Natural Gas Stoves Natural gas cooking appliances, which are used by a third of U.S. households, can contribute to poor indoor air quality, especially when used without an exhaust hood. Gas stoves emit nitrogen dioxide (NO2), carbon monoxide (CO), and formaldehyde (HCHO), each of which can exacerbate various respiratory and other health ailments. I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indoor air

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 2016