Improved procedures for the determination of lipid phosphorus by malachite green.

نویسندگان

  • X Zhou
  • G Arthur
چکیده

We have developed two procedures for the measurement of lipid phosphorus based on interaction between phosphomolybdenum and malachite green. One method, the "micro" assay uses 50-200 microliters of HClO4 and has a sensitivity range of 0.01-1.5 micrograms phosphorus. The second method, the "macro" assay, has a sensitivity range of 0.03-5.0 micrograms phosphorus with 100-500 microliters HClO4. Both assays are very reproducible with day to day standard deviations of less than 6% between triplicates irrespective of the HClO4 content used. At different concentrations of HClO4, each method was successfully used to determine the phosphorus content in phosphatidylethanolamine and sphingomyelin standards that covered the proposed sensitivity ranges. The increased range, sensitivity and greater volumes of HClO4 permitted in the procedures represent significant improvements over existing methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrophotometric determination of trace amount of malachite green from water with novel magnetic silica nanoparticles

A nano-hybrid based on polystyrene derivatives and magnetite was introduced as a new sorbent for pretreatment and determine the trace amount of malachite green from aqueous solution by spectrophotometry after preconcentration by solid phase extraction (SPE). UV–Vis spectrophotometer was used for determination of MG concentration after desorption of the dye by hydrochloric acid solution in the s...

متن کامل

Removal of Methylene Blue, Malachite Green and Rhodamine B in a Ternary System by Pistachio Hull; Application of Wavelet Neural Network Modeling and Doehlert Design

Most of previous papers in the field of dye removal used one dye or dyes with nearly separate spectra that simplifies dyes concentration determination by Beer's law at different λmax. In many real situations, dyes with highly overlapped spectra exist and their concentrations can be determined by multivariate analysis methods. In this study, principal component-wavelet neural network (PC-WNN) wa...

متن کامل

Synthesis and characterization of new spinel Mn0.5Cu0.5Cr2O4 and degradation of Malachite Green from wastewater in comparison with CuCr2O4

In this study phase- pure new spinel structure, Mn0.5Cu0.5Cr2O4 was prepared by hydrothermal method successfully and the degradation of Malachite green as an organic pollutant was investigated and compared with CuCr2O4. Purification of obtained nanoparticles was measured by using X-ray diffraction method (XRD) in which crystal st...

متن کامل

Photocatalytic degradation of Malachite Green using ZnO and ZnOTiO2 nanoparticles from aqueous solution

Today, despite the increasing demands for the products of chemical industries and the relatedfactories, the challenges of environmental pollution have not been improved and it is approaching avery dangerous stage. In this regard, the role of dyeing industries in contaminating the environment isundeniable. In this research, ZnO and ZnO-TiO2 nanoparticles were synthesized by co-...

متن کامل

A malachite green colorimetric assay for protein phosphatase activity.

A simple and sensitive colorimetric assay for protein phosphatase activity based on the determination of released Pi by an improved malachite green procedure (A. A. Baykov, O. A. Evtushenko, and S.M. Avaeva, 1988, Anal. Biochem. 171, 266-270) is described. Proteins must be removed or stabilized prior to Pi determination with 0.25 N sulfuric acid or 3% (w/w) perchloric acid. Alternatively, to av...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of lipid research

دوره 33 8  شماره 

صفحات  -

تاریخ انتشار 1992