Systemic cyclosporin A in high failure risk, repeated corneal transplantation.

نویسندگان

  • S Rumelt
  • V Bersudsky
  • T Blum-Hareuveni
  • U Rehany
چکیده

AIM To evaluate the efficacy of oral cyclosporin A in the prevention and treatment of immune graft rejection in heavily vascularised, repeated keratoplasties with high risk for failure. METHODS 21 consecutive patients with 28 repeated corneal transplants and four quadrant vascularised recipient bed were treated with oral cyclosporin A for an average period of 12 months (range 1-41 months) and followed for an average period of 26.6 months (range 6-106 months). The average cyclosporin A blood level was 325 ng/ml (range 180-421 ng/ml). Within this group of 21 patients, another 12 regrafts were not treated with cyclosporin A and served as a control group. RESULTS Nine of the 28 regrafts (32%) treated with cyclosporin A remained clear. The Kaplan-Meier curve showed a constant decline in survival of the treated grafts, although the survival proportion during the first year of treatment was statistically higher for the treated group compared with the untreated group. Once immune regraft rejection occurred, the regraft failed despite treatment with cyclosporin A and extensive topical and systemic corticosteroids. Nine regrafts (32%) had immune graft rejection and all ultimately failed compared with five in the untreated regrafts (42%, p = NS). Ten other regrafts (36%) in the treatment group failed due to causes other than immune regraft rejection. CONCLUSIONS Systemic cyclosporin A has a limited beneficial effect in preventing immune graft rejection in repeated corneal transplants in a highly vascularised corneal bed. When immune graft rejection occurs in such regrafts, the prognosis is poor despite aggressive medical treatment. Causes other than immune regraft rejection may also result in poor visual outcome in patients with clear regrafts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CLINICAL SCIENCE Systemic cyclosporin A in high failure risk, repeated corneal transplantation

Aim: To evaluate the efficacy of oral cyclosporin A in the prevention and treatment of immune graft rejection in heavily vascularised, repeated keratoplasties with high risk for failure. Methods: 21 consecutive patients with 28 repeated corneal transplants and four quadrant vascularised recipient bed were treated with oral cyclosporin A for an average period of 12 months (range 1–41 months) and...

متن کامل

Risk Factors for Failure of Keratoplasty in Keratoconus: Penetrating vs. Deep Anterior Lamellar Keratoplasty

Purpose: To determine the etiologic factors on rejection and failure rates and ocular surface changes after corneal transplantation by either DALK or PKP, in cases of keratoconus (KCN). Methods: In this cross-sectional study, considering the existing data, patients with keratoconus referring to Labbafinejad Medical Center from 2006 to 2016, who underwent corneal transplantation, were enrolled a...

متن کامل

Mycophenolate mofetil versus cyclosporin A in high risk keratoplasty patients: a prospectively randomised clinical trial.

BACKGROUND/AIMS The requirement for an effective, minimally toxic immunosuppressive agent remains a major obstacle to performing high risk corneal transplantation. Although therapy with cyclosporin A (CSA) allows superior graft survival, its use is limited because of a wide range of side effects. Mycophenolate mofetil (MMF) has been shown to be a safe and effective immunosuppressive agent follo...

متن کامل

Prolonged survival of allogeneic corneal grafts in rabbits treated with topically applied cyclosporin A: systemic absorption and local immunosuppressive effect.

The modes of action of topical cyclosporin A were studied in rabbits. Immunorejection of corneal allografts was provoked by placing the grafts eccentrically, in contact with the limbus. Topical application of cyclosporin A five times daily for 28 days prevented the rejection of corneal allografts. All grafts were rejected in the control animals. The seven rabbits of the cyclosporin A group were...

متن کامل

Systemic Immunomodulatory Strategies in High-risk Corneal Transplantation

The cornea is the most commonly transplanted tissue in the body. Although corneal grafts generally have high success rates, transplantation onto inflamed and vascularized host beds, or so-called high-risk corneal transplantation, has a high rate of graft rejection. The management of this high-risk corneal transplantation is challenging and involves numerous measures. One of the key measures to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 86 9  شماره 

صفحات  -

تاریخ انتشار 2002