Clinical feasibility of high-resolution single-shot diffusion tensor trace -weighted (ssTW) MRI
نویسندگان
چکیده
and negative (red) bipolar gradients results in cancelling contributions from off-diagonal diffusion tensor elements to the DW signal. Figure 2: A. Trace weighted MRIs acquired using our ssTW method in 15s across the entire brain. B. Brain tissue regions-of-interest (ROIs) C. Mean ADC map calculated from the ssTW scan. D. Mean ADC map calculated using DTI with 20 directions in 2 min. E. Direction-encoded color (DEC) fractional anisotropy map derived from the DTI scan. Clinical feasibility of high-resolution single-shot diffusion tensor trace -weighted (ssTW) MRI Alexandru V Avram, Joelle E Sarlls, Raisa Z Freidlin, and Peter J Basser Section on Tissue Biophysics and Biomimetics, NICHD, National Institutes of Health, Bethesda, MD, United States, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD, United States, Division of Computational Bioscience, CIT, National Institutes of Health, Bethesda, Maryland, United States
منابع مشابه
Diffusion-weighted single-shot line scan imaging of the human brain.
Single-shot line scan imaging (LSI) was adapted to diffusion-weighted (DW) MRI by replacing the initial 90 degrees radiofrequency pulse of the underlying high-speed stimulated echo sequence by a DW spin-echo preparation period. Implementation on a 2. 0 T whole-body MRI system yielded DW images of the human brain with b factors of 750 s mm(-2) and total imaging times of about 500 ms either for a...
متن کاملRapid isotropic diffusion mapping without susceptibility artifacts: whole brain studies using diffusion-weighted single-shot STEAM MR imaging.
A subsecond magnetic resonance imaging (MRI) technique for isotropic diffusion mapping is described which, in contrast to echo-planar imaging (EPI), is insensitive to resonance offsets, i.e., tissue susceptibility differences, magnetic field inhomogeneities, and chemical shifts. It combines a diffusion-weighted (DW) spin-echo preparation period and a high-speed stimulated echo acquisition mode ...
متن کاملSuperresolution in MRI: application to human white matter fiber tract visualization by diffusion tensor imaging.
A superresolution algorithm was applied to spatially shifted, single-shot, diffusion-weighted brain images to generate a new image with increased spatial resolution. Detailed two-dimensional white matter fiber tract maps of the human brain resulting from application of the technique are shown. The method provides a new means for improving the resolution in cases where k-space segmentation is di...
متن کاملRobust fat suppression at 3T in high-resolution diffusion-weighted single-shot echo-planar imaging of human brain.
Single-shot echo-planar imaging is the most common acquisition technique for whole-brain diffusion tensor imaging (DTI) studies in vivo. Higher field MRI systems are readily available and advantageous for acquiring DTI due to increased signal. One of the practical issues for DTI with single-shot echo-planar imaging at high-field is incomplete fat suppression resulting in a chemically shifted fa...
متن کاملHigh-field diffusion tensor imaging of mouse brain in vivo using single-shot STEAM MRI.
Information about the microstructural organization of cerebral white matter that is accessible by magnetic resonance diffusion tensor imaging (DTI) gains increasing importance for studies of animal brain. Particular challenges occur for in vivo conditions as well as at high magnetic fields. Here, we have employed a diffusion-weighted (DW) single-shot STEAM MRI sequence for DTI of mouse brain in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012