Precision Lifetime Measurements Using the Recoil Distance Method

نویسنده

  • R. Krücken
چکیده

The recoil distance method (RDM) for the measurements of lifetimes of excited nuclear levels in the range from about 1 ps to 1000 ps is reviewed. The New Yale Plunger Device for RDM experiments is introduced and the Differential Decay Curve Method for their analysis is reviewed. Results from recent RDM experiments on SD bands in the mass-190 region, shears bands in the neutron deficient lead isotopes, and ground state bands in the mass-130 region are presented. Perspectives for the use of RDM measurements in the study of neutron-rich nuclei are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sub-Nanosecond Lifetime Measurement Using the Recoil-Distance Method

The electromagnetic properties of low-lying nuclear states are a sensitive probe of both collective and single-particle degrees of freedom in nuclear structure. The recoil-distance technique provides a very reliable, direct and precise method for measuring lifetimes of nuclear states with lifetimes ranging from less than one to several hundred picoseconds. This method complements the powerful, ...

متن کامل

Collectivity and configuration mixing in 186,188Pb and 194Po.

Lifetimes of prolate intruder states in 186Pb and oblate intruder states in 194Po have been determined by employing, for the first time, the recoil-decay tagging technique in recoil distance Doppler-shift lifetime measurements. In addition, lifetime measurements of prolate states in 188Pb up to the 8+ state were carried out using the recoil-gating method. The B(E2) values have been deduced from...

متن کامل

Shape and structure of N=Z 64Ge: electromagnetic transition rates from the application of the recoil distance method to a knockout reaction.

Transition rate measurements are reported for the 2(1)+ and 2(2)+ states in N=Z 64Ge. The experimental results are in excellent agreement with large-scale shell-model calculations applying the recently developed GXPF1A interactions. The measurement was done using the recoil distance method (RDM) and a unique combination of state-of-the-art instruments at the National Superconducting Cyclotron L...

متن کامل

Recoil - distance lifetime measurements of V levels

Lifetimes for a number of level. s in 4 V have been measured using the recoil-distance technique. The experimental results for the mean lifetimes are 8.8+1.4 psec for the 428keV 5+ level, 21.6+1.1 psec for the 613-keV 4+ level, 111+9 psec for the 627-keV 6+ level, 6.7+ 1.8 psec for the 1056-keV 3 level, and 6, 5+ 0.5 psec for the 1099-keV 4~ ~ level. Lifetime l.imits were measured for other lev...

متن کامل

Direct Lifetime Measurements of the Excited States in (72)Ni.

The lifetimes of the first excited 2^{+} and 4^{+} states in ^{72}Ni were measured at the National Superconducting Cyclotron Laboratory with the recoil-distance Doppler-shift method, a model-independent probe to obtain the reduced transition probability. Excited states in ^{72}Ni were populated by the one-proton knockout reaction of an intermediate energy ^{73}Cu beam. γ-ray-recoil coincidences...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 105  شماره 

صفحات  -

تاریخ انتشار 2000