The Reliability of Strength Tests Performed In Elevated Shoulder Positions Using a Handheld Dynamometer.

نویسندگان

  • Sally J McLaine
  • Karen A Ginn
  • Cecilia M Kitic
  • James W Fell
  • Marie-Louise Bird
چکیده

CONTEXT The reliable measurement of shoulder strength is important when assessing athletes involved in overhead activities. Swimmers' shoulders are subject to repetitive humeral elevation and consequently have a high risk of developing movement-control issues and pain. Shoulder-strength tests performed in positions of elevation assist with the detection of strength deficits that may affect injury and performance. The reliability of isometric strength tests performed in positions of humeral elevation without manual stabilization, which is a typical clinical scenario, has not been established. OBJECTIVE To establish the relative and absolute intrarater reliability of shoulder-strength tests functional to swimming in 3 body positions commonly used in the clinical setting. DESIGN Repeated-measures reliability study. SETTING Research laboratory. SUBJECTS 15 university students and staff (mean ± SD age 24 ± 8.2 y). INTERVENTION Isometric shoulder-strength tests were performed in positions of humeral elevation (flexion and extension in 140° abduction in the scapular plane, internal and external rotation in 90° abduction) on subjects without shoulder pain in supine, prone, and sitting. Subjects were tested by 1 examiner with a handheld dynamometer and retested after 48 h. MAIN OUTCOME MEASURES Relative reliability (ICC3,1) values with 95% CI. Absolute reliability was reported by minimal detectable change (MDC). RESULTS Good to excellent intrarater reliability was found for all shoulder-strength tests (ICC .87-.99). Intrarater reliability was not affected by body position. MDC% was <16% for every test and ≤11% for tests performed in supine. CONCLUSIONS Shoulder flexion, extension, and internal- and external-rotation strength tests performed in humeral elevation demonstrated excellent to good intrarater reliability regardless of body position. A strength change of more than 15% in any position can be considered meaningful.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of 3 methods for assessing shoulder strength.

The reliability of tests for isometric strength of the shoulder joint in symptomatic subjects has yet to be established. For this purpose, interrater and intrarater agreement trials were undertaken to ascertain the reliability of manual muscle tests, a handheld dynamometer, and a spring-scale dynamometer for 5 different shoulder movements in symptomatic subjects. Intraclass correlation coeffici...

متن کامل

Test-retest reliability of isometric shoulder muscle strength measurement with a handheld dynamometer and belt

[Purpose] The aim of this study was to develop a method of measuring isometric shoulder joint muscle strength using a handheld dynamometer with a belt and investigate its test-retest reliability. [Subjects] The subjects comprised 40 healthy adults. [Methods] Six types of isometric shoulder muscle strength were measured twice, and reliability was assessed. [Results] The intraclass correlation co...

متن کامل

Effects of examiner strength on reliability of hip-strength testing using a handheld dynamometer.

CONTEXT Hip-muscle impairments are associated with a variety of lower-extremity dysfunctions. Accurate assessment in the clinical setting can be challenging due to the strength of hip muscles relative to examiner strength. OBJECTIVE To examine the influence of examiner strength and technique on manual hip-strength testing using a handheld dynamometer. DESIGN Repeated measures. SETTING Res...

متن کامل

Measuring seated hip extensor strength using a handheld dynamometer: an examination of the reliability and validity of the protocol

[Purpose] The purpose of this study was to examine the reliability and validity of measurements of hip extensor muscle strength using a handheld dynamometer (HHD) with subjects in a sitting position. In doing so, we also aimed to establish a modified method of measurement for patients with flexion contractures in the trunk and lower extremities. [Subjects and Methods] In 20 healthy males, hip e...

متن کامل

Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt

[Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subj...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of sport rehabilitation

دوره Technical Report  شماره 

صفحات  -

تاریخ انتشار 2016