Use of the laryngeal tube as a dedicated airway during tracheal intubation.
نویسندگان
چکیده
687±92 2 Dewey RC, Pieper HP, Hunt WE. Experimental cerebral hemodynamics. Vasomotor tone, critical closing pressure, and vascular bed resistance. J Neurosurg 1974; 41: 597±606 3 Aaslid R, Lundar T, Lindegaard K-F, Nornes H. Estimation of cerebral perfusion pressure from arterial blood pressure and transcranial Doppler recordings. In: Miller JD, Teasdale GM, Rowan JO, Galbraith SL, Mendelow AD, eds. Intracranial Pressure VI. Berlin: Springer, 1986; 226±9 4 Belfort MA, Saade GR, Yared M, et al. Change in estimated cerebral perfusion pressure after treatment with nimodipine or magnesium sulfate in patients with preeclampsia. Am J Obstet Gynecol 1999; 181: 402±7 5 Czosnyka M, Matta BF, Smielewski P, Kirkpatrick P, Pickard JD. Cerebral perfusion pressure in head-injured patients: a non-invasive assessment using transcranial Doppler ultrasonography. J Neurosurg 1998; 88: 802±8 6 Czosnyka M, Smielewski P, Piechnik S, Steiner LA, Pickard JD. Cerebral autoregulation following head injury. J Neurosurg 2001; 95: 756±63 7 Athanassiou L, Hancock SM, Mahajan RP. In vitro estimation of cerebral critical closing pressure during simulation of intracranial hypertension. Br J Anaesth 2002; 88: 317P 8 Stacey M, Moppett I, Athanassiou L, Mahajan RP. The effect of systemic compliance on the non-invasive assessment of zero ̄ow pressure in a bench model of pulsatile ̄ow. Br J Anaesth 2002; 89: 196P 9 Hancock SM, Mahajan RP, Athanassiou L. Non-invasive assessment of cerebral perfusion pressure and zerōow pressure in healthy volunteers: effects of changes in carbon dioxide. Br J Anaesth 2001; 87: 175P 10 Hancock SM, Mahajan RP, Athanassiou L. Non-invasive assessment of cerebral perfusion pressure and zerōow pressure in healthy volunteers: effects of changes in end-tidal carbon dioxide. Anesth Analg (in press) 11 Weyland A, Buhre W, Grund S, et al. Cerebrovascular tone rather than intracranial pressure determines the effective downstream pressure of cerebral circulation in the absence of intracranial hypertension. J Neurosurg Anesthesiol 2000; 12: 210±16
منابع مشابه
مقایسه مقاومت و کمپلیانس دینامیک راه هوایی بین لوله تراشه کافدار و لوله لارنژیال در بیهوشی داخل وریدی کامل(TIVA) Comparing Air Way Resistance and Dynamic Compliance of Tracheal Tube and Laryngeal Tube in TIVA
Background & Aim: The aim of this study was to compare air way resistance and dynamic compliance of tracheal tube and laryngeal tube in TIVA(Total Intravenous Anesthesia). Nowadays, low airway resistance and dynamic compliance improvement during the mechanical ventilation whether in ICU or during general anesthesia, especially in patients with pulmonary diseases, is a favorable purpose to c...
متن کاملComparison of the effect of thiopental sodium-midazolam combination on the hemodynamic response between tracheal intubation and laryngeal mask airway insertion: A clinical trial study
Background and Aim: The purpose of this study was to compare the effect of thiopental sodium-midazolam combination on the stress response and hemodynamic changes between tracheal intubation and laryngeal mask airway insertion during airway management. Materials and Methods: In this clinical trial study, 70 patients ASA 1, 2 candidates for elective surgery were randomly divided into two groups o...
متن کاملبررسی مقایسه ای دوروش لوله گذاری تراکئال بااستفاده ازگلایدوسکوپ وماسک حنجره برمیزان موفقیت و سرعت انتوباسیون توسط افراد غیر ماهر
Aim and background: Tracheal intubation remains the choice method for keeping airways open during mechanical ventilation. Among the various methods, standard method of direct laryngoscopy generally used by non-skilled staff increases the risk of failure. This study was performed to evaluate and compare the results of tracheal intubation using laryngeal masks vs. glidescope led by novice personn...
متن کاملTracheal Intubation with Aura-i and aScope-2: How to Minimize Apnea Time in an Unpredicted Difficult Airway
The supraglottic airway's usefulness as a dedicated airway is the subject of continuing development. We report the case of an obese patient with unpredicted difficult airway management in which a new "continuous ventilation technique" was used with the Aura-i laryngeal mask and the aScope-2 devices. The aScope-2/Aura-i system implemented airway devices for the management of predictable/unpredic...
متن کاملNew airways for resuscitation?
Over the last 15 years supraglottic airway devices (SADs), most notably the classic laryngeal mask airway (LMA) have revolutionised airway management in anaesthesia. In contrast for resuscitation, both in and outside hospital, facemask ventilation and tracheal intubation remain the mainstays of airway management. However there is evidence that both these techniques have complications and are of...
متن کاملLaryngo-tracheal ultrasonography to confirm correct endotracheal tube and laryngeal mask airway placement
Waveform capnography was recommended as the most reliable method to confirm correct endotracheal tube or laryngeal mask airway placements. However, capnography may be unreliable during cardiopulmonary resuscitation and during low flow states. It may lead to an unnecessary removal of a well-placed endotracheal tube, re-intubation and interruption of chest compressions. Real-time upper airway (la...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 90 3 شماره
صفحات -
تاریخ انتشار 2003