Literature review of condensation and evaporation of R290

نویسندگان

  • Cichong Liu
  • Ziyang Sun
  • Ziqi Zhang
  • Junye Shi
  • Jiangping Chen
  • Cichong LIU
  • Ziyang SUN
  • Ziqi ZHANG
  • Junye SHI
  • Jiangping CHEN
چکیده

Nowadays, an increasing attention in environmental issues including the global warming effect and ozone layer depletion has been attracted. R22 is urged to be ruled out until 2020 and 2030 for developed and developing countries. R290 (propane) has been regarded as a promising alternative refrigerant for the air-conditionings. However, R290 has different thermo-physical properties than conventional refrigerants and it would influence the application in tubes such as shear forces, gravity and surface tension. The condensation and evaporation behavior of R290 would have a great effect in designing suitable heat exchanger for R290. In recent years, researchers have made great efforts in studying different working fluids behaviors and multiple semi-empirical correlations have been established to predict the heat transfer and pressure drop while the study about R290 behavior is very limited. According to the past experiences in condensation and evaporation studies, the semi-empirical models may be not very accurate in the working conditions outside the range where they are established. This paper presents a detailed review of research work done on the condensation and evaporation of R290. This paper is a starting point for future R290 studies and R290 applications in air conditioning systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaporation and Condensation Heat Transfer Performance of Flammable Refrigerants in a Brazed Plate Heat Exchanger

Average Nusselt numbers were measured for R22, R290, R290/600a, and R32/152a undergoing evaporation and condensation in a brazed plate heat exchanger. The refrigerants experienced wavy, stratified flow at low heat and mass fluxes, 1.3 kW/m2 to 8.3 kW/m2 and 1.6 kg/m2 s to 19 kg/m 2 s, respectively. Heat transfer correlations from the literature for in-tube and channel flow of refrigerants with ...

متن کامل

A Performance comparison of vapour compression refrigeration system using various alternative refrigerants

A performance analysis on a vapour compression refrigeration system with various refrigerants mixture of R152a, RE170, R600a, and R290 were done for various mixture ratios and their results were compared with R134a as possible alternative replacement. The results showed that all of the alternative refrigerants investigated in the analysis except R431A, [R 152a (29%), R290 (71%)] have a slightly...

متن کامل

Experimental Analysis of Alternative Refrigerant as Replacement of Hfc134a

An experimental performance study on VCR system with 100g R600a/R290 refrigerant mixture and 100g R600a (pure isobutene) as drop in replacement of R134a was conducted . continuation running tests were performed under different length of capillary for R600a/R290 & R600a. The result showed that the hydrocarbon mixture (R600a/R290) had highest COP at L=10 feet length capillary by17.35% -23.5% for ...

متن کامل

Testing of Environment Friendly Refrigerant R290 for Water Cooler Application (RESEARCH NOTE)

This paper presents environment friendly refrigerant R290 as a solution to the environmental concerns like depletion of ozone layer and rise in global warming because of wide use of synthetic refrigerants R22 and R134a. The water cooler is the widely used refrigeration application in warm climatic countries. Refrigerant R22 and R134a are predominantly used refrigerants in water cooler refrigera...

متن کامل

The Role of Partial Internal Wetting in Hysteresis Behavior of Catalyst Pellet

The phenomenon of capillary condensation is studied through the weight change of condensed phase in an internally wetted porous pd catalyst pellet during the course of exothermic reacation of cyclohexane hydrogenation in a thermogravimetric analyzer (TGA). The direct measurement of condensed phase indicates that evaporation of condensed phase is confined to the macropores of catalyst pellet at ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016